Maybe you already knew:
on WASY website there's a movie about setting ET dependent on depth to
groundwater.
You don't need to use the unsaturated module.
http://www.wasy.de/english/produkte/feflow/howto/video_evapotranspiration..htm
I haven't tried it yet, so I can't give you any suggest.
Giovanni Formentin
----- Original Message -----
From: bbarnett40
To: feflow@...
Sent: Thursday, April 24, 2008 12:53 AM
Subject: [feflow] Re: Evapotranspiration
Hi Gio
Thanks for the response.
There are several options in FEFLOW to provide a flux of water from
the water table. However to represent evapotranspiration in an
appropriate manner we need to make the magnitude of the flux
inversely dependent on water table depth ie the flux decreases as
water table gets deeper.
Brian
--- In feflow@..., Giovanni <g.firmani@...> wrote:
>
> Why dont you try to use the recharge with a negative value?
>
> Gio
>
>
> 2008/4/23, bbarnett40 <bbarnett@...>:
>
> > We are currently exploring methods of improving the
representation of
> > evapotranspiration in FEFLOW without having to use the
unsaturated zone
> > package. Has anyone considered this problem and are there any
> > interface modules that others have developed to model
> > evapotranspiration?
>