I remembered that with the version 5.0 and 5.1, one can plot the hydrograph
by using a free IFM that is developed and downloadable from wasy’s website
(www.wasy.de). I am not sure if it is still available in the new version,
but I think it should have some function like that.
About the second question, I am not sure if I understood it correctly too.
If he means to assign the point aquifer property obtained from the scatter
boreholes, he can prepare a pnt file, and do the interpolation for the whole
model domain. But the quality of the interpolation will depend on the
numbers of data points and how large of the model domain.
Regards
Jinhui
From: feflow@... [mailto:feflow@...] On Behalf
Of syed hashmath
Sent: November 9, 2007 8:12 AM
To: feflow@...
Subject: Re: [feflow] Calibration
I guess borja in second question is talking about automatic calibration.
Michael Verreault <michael.verreault@...
<mailto:michael.verreault%40labosl.ca> > wrote:
Feflow is not like MODFLOW and don't allow to plot graph of simulated vs
observed head.
You have to export *.dar files in the postprocess of your model and to plot
data on a graph (for example Excel).
I don't really understand the second question.
Regard's,
Michael Verreault, ing., M.Sc.A.
Hydrogéologue
Resp. Hydrogéologie et Environnement
Les Laboratoires SL
1309, blv. St-Paul
Chicoutimi, QC, G7J 3Y2
Tel: 418-698-6827
Fax: 418-543-6812
michael.verreault@... <mailto:michael.verreault%40labosl.ca>