MODFLOW have a special version that may suit your purpose. Please check the usgs
website, I think it is called GWM.
http://pubs.usgs.gov/of/2005/1072/
Regards
Jinhui
From: feflow@... [mailto:feflow@...] On Behalf
Of lenin kalyanasundaram
Sent: 2007Äê4ÔÂ15ÈÕ 20:12
To: gwmodel; hydforum; seawat; visual-modflow; feflow
Subject: [feflow] Help source code for ground water optimization - Reg
Dear Members,
i am doing research on ground water optimization for coastal region. i need
to optimize pumping rate, etc..,. so i want any GW optimization program with
source code to learn and understand. Please share your ideas and help me in
this regard. if you have any query do mail me.
With Regards
Lenin
Reserach Scholar
Anna University
Chennai
Dear Members,
i am doing research on ground water optimization for coastal region. i need to
optimize pumping rate, etc..,. so i want any GW optimization program with source
code to learn and understand. Please share your ideas and help me in this
regard. if you have any query do mail me.
With Regards
Lenin
Reserach Scholar
Anna University
Chennai
I would like to apologize for the last email I sent. I noticed a stupid
thing I have done in the model. The fixed constant head I assigned for
the drain is lower that the constant heads of the upstream and
downstream BC for this reason the sum of the fluxes from these borders
are equal to the total flux in the model.
Please forgive me ,,, I am a new user of the program :)
Thank you for the attention
Giovanni Firmani
Dear all
I am a new feflow user ! I hope you can help me.
I am currently using the version 5.2 installed in a pc with win XP SP2.
I am trying to test the reliability of the "budget analyser" with a very
simple model. I have attached the following model:
Dimension of the domain: 2D vertical
B.C. :constant Head (30 m) upstream , costant head (28m) downstream, a
drainage modelled as a costant head (25 m) in the middle of the domain
I would like to evaluate the flux I can extract from the drain. Using the
budget analyser I have got the absolute value of 226.16 m3/day for the in
and out flux. then I used the fluid flux analyser in order to get the flux
upstream and downstream . the values are rispectively 144.185 m3/day
(positive) and 81.977 m3/day (negative). For the upstream BC I was expecting
the same value I have got with the budget analyser why is it different? Is I
sum the two previous values I obtai exactly 226.16 m3/day, how is it
possible?
if you have any idea please let me know
Kind regards
Giovanni
When I make a back ground in femap of feflow , I get some troubles.
1. I launch feflow map assistant,then open a .bmp format file .
2. define the image coordinates in four points; typing the image
coordinates in the corresponding fields of the reference points table.
3. Click on the "Register" button; Click on the "Rectify" button.
4. a black board pops up,nothing on the picture.
5. I save this picture in .tif,then I open it in the feflow by
quick access load map,still I can¡¯t see the background,only black
board .
Who can explain this ,thanks
Hi to everybody!
I am attending the first official course of FEFLOW in Italy (Ferrara)
organized by WASY. With the other attendees we decided to create a new
italian FEFLOW mailing list. If you are italian and you want to
discuss about that program , join our first italian Feflow group:
feflow_italy@...
Kind regards
Giovanni Firmani
Hi,
1. Both can be done, you can assign initial hydraulic
head or topography, but I usually put topography.
2. No, you do not have to define initial hydraulic
head as different slice, just go...
Regards
Nanda Rinaldi
--- "C. P. Kumar" <cpkumar@...> wrote:
> Dear little willow,
>
> Thank you very much for your kind response and
> suggestions. It makes
> the things more clear to me. I understand that I
> have two options -
>
> (1) Assign elevations of initial hydraulic heads as
> Slice 1 (Free &
> movable). But in that case whether topography of the
> area will not be
> accounted in the simulations?
>
> (2) Assign topographic elevations of ground level as
> Slice 1
> as "Phreatic" (not sure if I am correct). In this
> case, whether
> initial hydraulic heads also need to be defined as
> another slice or
> they can automatically be accounted by initial flow
> conditions?
>
> Regards
> Kumar
>
>
> --- In feflow@..., little willow
> <little_willow71@...>
> wrote:
> >
> > Hi,
> >
> > It looks like that if the water table inside the
> first
> > layer is a 'strong' condition, then a moving mesh
> > according to water table can be used. Assigning
> > topography to the surface layer and assigning
> phreatic
> > surface can also be defined. If you assigned river
> > boundary just a bit below the height of topography
> > then obviously your problem become phreatic.
> > In general, phreatic surface is used in your case.
> >
> >
> > --- Tapas Karmaker <tapas_karmaker@...> wrote:
> >
> > > Dear Mr. Kumar,
> > >
> > > I have same type of problem. I assined top layer
> as
> > > Phreatic. You may not assign any boundary
> condition
> > > at the top layer.
> > >
> > > Sincerely,
> > >
> > > Tapas
> > >
> > >
> > > ----- Original Message ----
> > > From: C. P. Kumar <cpkumar@...>
> > > To: feflow@...
> > > Sent: Wednesday, January 24, 2007 11:50:37 AM
> > > Subject: [feflow] FEFLOW Model Setup Query
> > >
> > > Dear Group Member,
> > >
> > > I have few queries regarding model setup for
> FEFLOW.
> > >
> > >
> > > (1) To model unconfined coastal aquifer with two
> > > layers (top sand and
> > > bottom clay), I have prepared the following
> files:
> > >
> > > relief.trp - topographic elevations of ground
> level
> > > sand.trp - elevations of bottom of sand layer
> > > clay.trp - elevations of bottom of clay layer
> > >
> > > The groundwater lies in the top sand layer
> (around
> > > 15 m thick) which
> > > lies above the clay layer (around 1 - 2 m
> thick).
> > > With these two
> > > layers, I understand that Slice 2 and Slice 3
> can be
> > > assigned
> > > as "Fixed" slices but I am not sure about the
> top
> > > Slice 1.
> > >
> > > Can we assign relief.trp (topographic elevations
> of
> > > ground level) as
> > > Slice 1 - if yes, then should it be "Free &
> movable"
> > > or "Phreatic"
> > > (though actually it is fixed stratigraphic
> unit)? In
> > > that case,
> > > should flow initials (hydraulic head) should be
> > > assigned to Slice 1
> > > also (similar to Slice 2 & 3)?
> > >
> > > Can we assign elevations of initial hydraulic
> heads
> > > as Slice 1 (Free
> > > & movable) - in that case whether topographic
> > > elevations (relief.trp)
> > > are not required in the simulations?
> > >
> > > (2) The mesh is generated in two-dimensional
> plane
> > > and the third
> > > dimension is accounted by layers. Then how is
> > > vertical discretization
> > > accounted by the model? How can we get the
> vertical
> > > distribution of
> > > mass concentration values within a layer?
> > >
> > > I shall be grateful for any suggestions from the
> > > learned members in
> > > this group.
> > >
> > > Thanks & Regards
> > > Kumar
> > > ============ ========= ========= =========
> =========
> > > C. P. KUMAR
> > > Scientist 'E1'
> > > National Institute of Hydrology
> > > Jal Vigyan Bhawan
> > > Roorkee - 247667 (Uttaranchal)
> > > INDIA
> > >
> > > Web Page : http://www.angelfir e.com/nh/
> cpkumar/
> > > ============ ========= ========= =========
> =========
Dear mr Kumar,
The top of slice 1 could be assign by using your relief.trp file. You
could use free&movable for slice 1.
Your initial flow Hydraulic head could be the same for your two layers,
then you could assign the same initial flow for each slice.
you could use for slice 1 (top) free&movable , slice 2 undefined, slice
3 fixed
regards
Thierry BONTEMPS
Project Manager - Civil & Environmental Technologies Dpt
TRACTEBEL DEVELOPMENT ENGINEERING S.A.
---------------------------------------------------
Avenue Jean Monnet 1 - B 1348 Louvain-la-Neuve - BELGIUM
tel. + 32 10 477 830 - fax + 32 10 477 819
mailto:thierry.bontemps@...
<mailto:thierry.bontemps@...>
www.tde.tractebel.com <http://www.tde.tractebel.com/>
________________________________
From: feflow@... [mailto:feflow@...] On
Behalf Of C. P. Kumar
Sent: mercredi 24 janvier 2007 07:21
To: feflow@...
Subject: [feflow] FEFLOW Model Setup Query
Dear Group Member,
I have few queries regarding model setup for FEFLOW.
(1) To model unconfined coastal aquifer with two layers (top sand and
bottom clay), I have prepared the following files:
relief.trp - topographic elevations of ground level
sand.trp - elevations of bottom of sand layer
clay.trp - elevations of bottom of clay layer
The groundwater lies in the top sand layer (around 15 m thick) which
lies above the clay layer (around 1 - 2 m thick). With these two
layers, I understand that Slice 2 and Slice 3 can be assigned
as "Fixed" slices but I am not sure about the top Slice 1.
Can we assign relief.trp (topographic elevations of ground level) as
Slice 1 - if yes, then should it be "Free & movable" or "Phreatic"
(though actually it is fixed stratigraphic unit)? In that case,
should flow initials (hydraulic head) should be assigned to Slice 1
also (similar to Slice 2 & 3)?
Can we assign elevations of initial hydraulic heads as Slice 1 (Free
& movable) - in that case whether topographic elevations (relief.trp)
are not required in the simulations?
(2) The mesh is generated in two-dimensional plane and the third
dimension is accounted by layers. Then how is vertical discretization
accounted by the model? How can we get the vertical distribution of
mass concentration values within a layer?
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
<http://www.angelfire.com/nh/cpkumar/>
================================================
Dear Mr. Kumar,
as I understand it, you should use the option "Free & movable" if you don't mind
remembering where the topographic surface is: FEFLOW will move the first slice
down according to the actual position of the water table, given that you're
simulating saturated flow only. I think topography won't be taken into account.
Using "Phreatic", FEFLOW leaves the slice on the same vertical position you set
it initially (unless it goes over the top, in that case you can choose to let
FEFLOW change the layer to "confined" or let the layer expand over the
topographic surface).
Both cases should require initial heads to be assigned by the same way and
without adding any other slice.
Hope I've helped you,
kind regards
Giovanni Formentin
G.E.CO. snc
Legnano - Italy
----- Original Message -----
From: C. P. Kumar
To: feflow@...
Sent: Thursday, January 25, 2007 11:56 AM
Subject: [feflow] Re: FEFLOW Model Setup Query
Dear little willow,
Thank you very much for your kind response and suggestions. It makes
the things more clear to me. I understand that I have two options -
(1) Assign elevations of initial hydraulic heads as Slice 1 (Free &
movable). But in that case whether topography of the area will not be
accounted in the simulations?
(2) Assign topographic elevations of ground level as Slice 1
as "Phreatic" (not sure if I am correct). In this case, whether
initial hydraulic heads also need to be defined as another slice or
they can automatically be accounted by initial flow conditions?
Regards
Kumar
--- In feflow@..., little willow <little_willow71@...>
wrote:
>
> Hi,
>
> It looks like that if the water table inside the first
> layer is a 'strong' condition, then a moving mesh
> according to water table can be used. Assigning
> topography to the surface layer and assigning phreatic
> surface can also be defined. If you assigned river
> boundary just a bit below the height of topography
> then obviously your problem become phreatic.
> In general, phreatic surface is used in your case.
>
>
> --- Tapas Karmaker <tapas_karmaker@...> wrote:
>
> > Dear Mr. Kumar,
> >
> > I have same type of problem. I assined top layer as
> > Phreatic. You may not assign any boundary condition
> > at the top layer.
> >
> > Sincerely,
> >
> > Tapas
> >
> >
> > ----- Original Message ----
> > From: C. P. Kumar <cpkumar@...>
> > To: feflow@...
> > Sent: Wednesday, January 24, 2007 11:50:37 AM
> > Subject: [feflow] FEFLOW Model Setup Query
> >
> > Dear Group Member,
> >
> > I have few queries regarding model setup for FEFLOW.
> >
> >
> > (1) To model unconfined coastal aquifer with two
> > layers (top sand and
> > bottom clay), I have prepared the following files:
> >
> > relief.trp - topographic elevations of ground level
> > sand.trp - elevations of bottom of sand layer
> > clay.trp - elevations of bottom of clay layer
> >
> > The groundwater lies in the top sand layer (around
> > 15 m thick) which
> > lies above the clay layer (around 1 - 2 m thick).
> > With these two
> > layers, I understand that Slice 2 and Slice 3 can be
> > assigned
> > as "Fixed" slices but I am not sure about the top
> > Slice 1.
> >
> > Can we assign relief.trp (topographic elevations of
> > ground level) as
> > Slice 1 - if yes, then should it be "Free & movable"
> > or "Phreatic"
> > (though actually it is fixed stratigraphic unit)? In
> > that case,
> > should flow initials (hydraulic head) should be
> > assigned to Slice 1
> > also (similar to Slice 2 & 3)?
> >
> > Can we assign elevations of initial hydraulic heads
> > as Slice 1 (Free
> > & movable) - in that case whether topographic
> > elevations (relief.trp)
> > are not required in the simulations?
> >
> > (2) The mesh is generated in two-dimensional plane
> > and the third
> > dimension is accounted by layers. Then how is
> > vertical discretization
> > accounted by the model? How can we get the vertical
> > distribution of
> > mass concentration values within a layer?
> >
> > I shall be grateful for any suggestions from the
> > learned members in
> > this group.
> >
> > Thanks & Regards
> > Kumar
> > ============ ========= ========= ========= =========
> > C. P. KUMAR
> > Scientist 'E1'
> > National Institute of Hydrology
> > Jal Vigyan Bhawan
> > Roorkee - 247667 (Uttaranchal)
> > INDIA
> >
> > Web Page : http://www.angelfir e.com/nh/ cpkumar/
> > ============ ========= ========= ========= =========
Dear little willow,
Thank you very much for your kind response and suggestions. It makes
the things more clear to me. I understand that I have two options -
(1) Assign elevations of initial hydraulic heads as Slice 1 (Free &
movable). But in that case whether topography of the area will not be
accounted in the simulations?
(2) Assign topographic elevations of ground level as Slice 1
as "Phreatic" (not sure if I am correct). In this case, whether
initial hydraulic heads also need to be defined as another slice or
they can automatically be accounted by initial flow conditions?
Regards
Kumar
--- In feflow@..., little willow <little_willow71@...>
wrote:
>
> Hi,
>
> It looks like that if the water table inside the first
> layer is a 'strong' condition, then a moving mesh
> according to water table can be used. Assigning
> topography to the surface layer and assigning phreatic
> surface can also be defined. If you assigned river
> boundary just a bit below the height of topography
> then obviously your problem become phreatic.
> In general, phreatic surface is used in your case.
>
>
> --- Tapas Karmaker <tapas_karmaker@...> wrote:
>
> > Dear Mr. Kumar,
> >
> > I have same type of problem. I assined top layer as
> > Phreatic. You may not assign any boundary condition
> > at the top layer.
> >
> > Sincerely,
> >
> > Tapas
> >
> >
> > ----- Original Message ----
> > From: C. P. Kumar <cpkumar@...>
> > To: feflow@...
> > Sent: Wednesday, January 24, 2007 11:50:37 AM
> > Subject: [feflow] FEFLOW Model Setup Query
> >
> > Dear Group Member,
> >
> > I have few queries regarding model setup for FEFLOW.
> >
> >
> > (1) To model unconfined coastal aquifer with two
> > layers (top sand and
> > bottom clay), I have prepared the following files:
> >
> > relief.trp - topographic elevations of ground level
> > sand.trp - elevations of bottom of sand layer
> > clay.trp - elevations of bottom of clay layer
> >
> > The groundwater lies in the top sand layer (around
> > 15 m thick) which
> > lies above the clay layer (around 1 - 2 m thick).
> > With these two
> > layers, I understand that Slice 2 and Slice 3 can be
> > assigned
> > as "Fixed" slices but I am not sure about the top
> > Slice 1.
> >
> > Can we assign relief.trp (topographic elevations of
> > ground level) as
> > Slice 1 - if yes, then should it be "Free & movable"
> > or "Phreatic"
> > (though actually it is fixed stratigraphic unit)? In
> > that case,
> > should flow initials (hydraulic head) should be
> > assigned to Slice 1
> > also (similar to Slice 2 & 3)?
> >
> > Can we assign elevations of initial hydraulic heads
> > as Slice 1 (Free
> > & movable) - in that case whether topographic
> > elevations (relief.trp)
> > are not required in the simulations?
> >
> > (2) The mesh is generated in two-dimensional plane
> > and the third
> > dimension is accounted by layers. Then how is
> > vertical discretization
> > accounted by the model? How can we get the vertical
> > distribution of
> > mass concentration values within a layer?
> >
> > I shall be grateful for any suggestions from the
> > learned members in
> > this group.
> >
> > Thanks & Regards
> > Kumar
> > ============ ========= ========= ========= =========
> > C. P. KUMAR
> > Scientist 'E1'
> > National Institute of Hydrology
> > Jal Vigyan Bhawan
> > Roorkee - 247667 (Uttaranchal)
> > INDIA
> >
> > Web Page : http://www.angelfir e.com/nh/ cpkumar/
> > ============ ========= ========= ========= =========
>
Hi,
It looks like that if the water table inside the first
layer is a 'strong' condition, then a moving mesh
according to water table can be used. Assigning
topography to the surface layer and assigning phreatic
surface can also be defined. If you assigned river
boundary just a bit below the height of topography
then obviously your problem become phreatic.
In general, phreatic surface is used in your case.
--- Tapas Karmaker <tapas_karmaker@...> wrote:
> Dear Mr. Kumar,
>
> I have same type of problem. I assined top layer as
> Phreatic. You may not assign any boundary condition
> at the top layer.
>
> Sincerely,
>
> Tapas
>
>
> ----- Original Message ----
> From: C. P. Kumar <cpkumar@...>
> To: feflow@...
> Sent: Wednesday, January 24, 2007 11:50:37 AM
> Subject: [feflow] FEFLOW Model Setup Query
>
> Dear Group Member,
>
> I have few queries regarding model setup for FEFLOW.
>
>
> (1) To model unconfined coastal aquifer with two
> layers (top sand and
> bottom clay), I have prepared the following files:
>
> relief.trp - topographic elevations of ground level
> sand.trp - elevations of bottom of sand layer
> clay.trp - elevations of bottom of clay layer
>
> The groundwater lies in the top sand layer (around
> 15 m thick) which
> lies above the clay layer (around 1 - 2 m thick).
> With these two
> layers, I understand that Slice 2 and Slice 3 can be
> assigned
> as "Fixed" slices but I am not sure about the top
> Slice 1.
>
> Can we assign relief.trp (topographic elevations of
> ground level) as
> Slice 1 - if yes, then should it be "Free & movable"
> or "Phreatic"
> (though actually it is fixed stratigraphic unit)? In
> that case,
> should flow initials (hydraulic head) should be
> assigned to Slice 1
> also (similar to Slice 2 & 3)?
>
> Can we assign elevations of initial hydraulic heads
> as Slice 1 (Free
> & movable) - in that case whether topographic
> elevations (relief.trp)
> are not required in the simulations?
>
> (2) The mesh is generated in two-dimensional plane
> and the third
> dimension is accounted by layers. Then how is
> vertical discretization
> accounted by the model? How can we get the vertical
> distribution of
> mass concentration values within a layer?
>
> I shall be grateful for any suggestions from the
> learned members in
> this group.
>
> Thanks & Regards
> Kumar
> ============ ========= ========= ========= =========
> C. P. KUMAR
> Scientist 'E1'
> National Institute of Hydrology
> Jal Vigyan Bhawan
> Roorkee - 247667 (Uttaranchal)
> INDIA
>
> Web Page : http://www.angelfir e.com/nh/ cpkumar/
> ============ ========= ========= ========= =========
Dear Mr. Kumar,
I have same type of problem. I assined top layer as Phreatic. You may not assign
any boundary condition at the top layer.
Sincerely,
Tapas
----- Original Message ----
From: C. P. Kumar <cpkumar@...>
To: feflow@...
Sent: Wednesday, January 24, 2007 11:50:37 AM
Subject: [feflow] FEFLOW Model Setup Query
Dear Group Member,
I have few queries regarding model setup for FEFLOW.
(1) To model unconfined coastal aquifer with two layers (top sand and
bottom clay), I have prepared the following files:
relief.trp - topographic elevations of ground level
sand.trp - elevations of bottom of sand layer
clay.trp - elevations of bottom of clay layer
The groundwater lies in the top sand layer (around 15 m thick) which
lies above the clay layer (around 1 - 2 m thick). With these two
layers, I understand that Slice 2 and Slice 3 can be assigned
as "Fixed" slices but I am not sure about the top Slice 1.
Can we assign relief.trp (topographic elevations of ground level) as
Slice 1 - if yes, then should it be "Free & movable" or "Phreatic"
(though actually it is fixed stratigraphic unit)? In that case,
should flow initials (hydraulic head) should be assigned to Slice 1
also (similar to Slice 2 & 3)?
Can we assign elevations of initial hydraulic heads as Slice 1 (Free
& movable) - in that case whether topographic elevations (relief.trp)
are not required in the simulations?
(2) The mesh is generated in two-dimensional plane and the third
dimension is accounted by layers. Then how is vertical discretization
accounted by the model? How can we get the vertical distribution of
mass concentration values within a layer?
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
============ ========= ========= ========= =========
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfir e.com/nh/ cpkumar/
============ ========= ========= ========= =========
Dear Group Member,
I have few queries regarding model setup for FEFLOW.
(1) To model unconfined coastal aquifer with two layers (top sand and
bottom clay), I have prepared the following files:
relief.trp - topographic elevations of ground level
sand.trp - elevations of bottom of sand layer
clay.trp - elevations of bottom of clay layer
The groundwater lies in the top sand layer (around 15 m thick) which
lies above the clay layer (around 1 - 2 m thick). With these two
layers, I understand that Slice 2 and Slice 3 can be assigned
as "Fixed" slices but I am not sure about the top Slice 1.
Can we assign relief.trp (topographic elevations of ground level) as
Slice 1 - if yes, then should it be "Free & movable" or "Phreatic"
(though actually it is fixed stratigraphic unit)? In that case,
should flow initials (hydraulic head) should be assigned to Slice 1
also (similar to Slice 2 & 3)?
Can we assign elevations of initial hydraulic heads as Slice 1 (Free
& movable) - in that case whether topographic elevations (relief.trp)
are not required in the simulations?
(2) The mesh is generated in two-dimensional plane and the third
dimension is accounted by layers. Then how is vertical discretization
accounted by the model? How can we get the vertical distribution of
mass concentration values within a layer?
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
================================================
Dear Group Member,
I have a small query regarding FEFLOW simulation. After setting-up
the model for simulating seawater intrusion in Goa coast (India), I
made initial test run for the following mass boundary condition along
the sea -
Mass (1st kind) = 3.5425 e+04 mg/l - Constrained by mass flux: Min. =
0, Max. = 3.5425 e+04 mg/l
Mass transport initials = 0 mg/l throughout the model domain.
Density ratio = 247.975 exp-4
However, with initial test simulation for 7300 days, I found that
many values of mass concentration are negative and many values are
exceeding 3.5425 e+04 mg/l in the model domain. I understand that the
simulated values must lie within 0 and 3.5425 e+04 mg/l (instead of
becoming negative and exceeding maximum).
Can you please suggest what could be the possible error in my model
setup? I shall be grateful for any suggestions from the learned
members in this group. I can send the .fem file if any member is
willing to examine the same.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/
================================================
I am considering purchasing FEFLOW as part of simulating changes in
flow fields associated with soil compaction. I have the following
questions related to its capability to allow for transient material
property inputs (such as hydraulic conductivity or specific storage).
1) what is the time level at which something like conductivity can
be changed, time-step, stress period?;
2) Are there constraints on the magnitude and/or spatial extent over
which such changes can be applied?
3) With a change in something like conductivity or storage, an
accompanying change in the head field will also need to occur. If
you change the conductivity at the start of a new stress period, how
does the model develop a revised head field? As part of the initial
time-steps or independent somehow?
4) What sort of model instabilities does changing hydraulic
conductivity in a zoned fashion create?
Thanks, I appreciate any feedback
Dear Group Member,
Using FEFLOW (for the first time), I have completed the model setup
for simulation of seawater intrusion in Goa coast (India). For
initial testing, the simulation run worked properly for "Flow Only".
However, for "transient flow and mass transport" simulation, I get
the following error message -
"FEFLOW - Groundwater Simulation System has encountered a problem and
needs to close. We are sorry for the inconveinence."
To rectify the above error, I tried vaious options under "Temporal &
control data" but could get the successful simulation run. Finally,
when I tested with "Density ratio" as zero under "Flow Materials",
the simulation run proceeded properly. It implies that a non-zero
density ratio (247.975 exp-4 given for the present study) for non-
linear coupled simulation is causing the problem.
Can you please suggest how to rectify this problem? I shall be
grateful for any suggestions from the learned members in this group.
I can send the .fem file if any member is willing to examine the same
for any possible errors.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/
================================================
M Kumar,
Answer about question 1
You can also import most values from shape files (Arc View or Arc info or
Mapinfo (using universal translator)) using ''assing'' ''database''. If you
re unagle to do that, check the structure of a TRP in the tutorial as
previously discussed.
Michael Verreault, ing., M.Sc.A.
Hydrogéologue
Resp. Hydrogéologie et Environnement
Les Laboratoires SL inc.
1309, blv. St-Paul
Chicoutimi (QC) G7J 3Y2
Tel: 418-698-6827
Fax: 418-543-6812
-------Message original-------
De : feflow@...
Date : 12/11/06 05:00:58
A : feflow@...
Sujet : [feflow] Digest Number 10
FEFLOW Users Group
Messages In This Digest (3 Messages)
1.1.
Model Setup for FEFLOW From: C. P. Kumar
1.2.
Re: Model Setup for FEFLOW From: little willow
1.3.
Re: Model Setup for FEFLOW From: Bontemps Thierry
View All Topics | Create New Topic Messages
1.1.
Model Setup for FEFLOW
Posted by: "C. P. Kumar" cpkumar@... cpkumar
Mon Dec 11, 2006 10:27 am
Dear Group Members,
Using FEFLOW (for the first time), I am in the process of model setup
for simulation of seawater intrusion in Goa coast (India). The
relevant details are briefly presented below.
[A] Background for taking-up the Study:
Coastal tracts of Goa (India) are rapidly being transformed into
settlement areas. The poor water supply facilities has encouraged
people to have their own source of water by digging wells. During the
last decade, there have been large-scale withdrawals of groundwater
by builders, hotels and other tourist establishments. Though the
seawater intrusion has not yet assumed serious magnitude, but in the
coming years it may turn to be a major problem if corrective measures
are not initiated at this stage.
[B] Objectives of the Study:
Simulation of seawater intrusion in a region along Goa coast (Bardez
taluk of North Goa); evaluation of the impact on seawater intrusion
due to various groundwater pumping scenarios; sensitivity analysis;
and suggestions for remedial measures.
[C] Laboratory and Field Investigations carried out:
* Identification of 20 observation wells; measurement of monthly
groundwater level data in observation wells (September 2004 to August
2005); collection of bi-monthly groundwater samples during September
2004 to May 2005.
* Based upon the bi-monthly measurements of salinity in laboratory,
groundwater quality in all the observation wells was found to be
reasonably fresh, both in pre- and post-monsoon periods. It can be
attributed to the fact that the transition zone of fresh water-saline
water lies below the shallow open wells (in shallow unconfined
aquifer to a depth of about 10 - 12 m below ground), as evidenced by
vertical electrical soundings.
* Resistivity profiling: Apparent electrical resistivity measured
along four profiles (at 10 m depth plane) from sea coast to 525
meters inland. The seawater mixed zone was witnessed along two
sections in the low lying sandy alluvial areas.
* Vertical electrical sounding: Carried out at 7 monitoring well
locations upto a depth of 20 metres. Only three wells in the study
area show low values of resistivity below 12 metres depth, indicating
the presence of seawater or mixed zone below this depth.
[D] Model Setup:
The study area map (boundary - dxf, rivers - dxf, location of
observation wells - pnt) has been digitized and an initial finite
element mesh has been created for the entire area. Design of slices
and layers (3D model) and flow and transport data (initials,
boundaries, materials) are still to be done. There is mostly single
aquifer system. In low lying areas, it is unconfined aquifer
consisting of sandy loam (upto 15 m) over unfractured hard rock. In
plateau areas, it is confined aquifer - laterite, clay and fractured
hard rock.
[E] MY QUERIES:
1. Many of the input data files for FEFLOW (initial distribution of
hydraulic head and mass concentration, river water levels, well
pumping rates, transmissivity, conductivity, aquifer top and bottom
elevation etc.) are required to be in the trp (ASCII) format. How
these input files are to be created? Whether FEFLOW itself allows
creation of such files or some outside method is needed and how to do
that?
2. There are large number of dugwells in the study area (reported
density = 18 wells/km2, draft rate = 155 to 259 m3/day). However,
locations of these wells (on map) and their actual drafts are not
available. In such case, how well drafts can be incorporated in the
simulations?
3. How to proceed with FEFLOW setup if we intend simulation only in
part of the study area, say upto around 2 to 3 km within the coast
(15 km long), which is more vulnerable to seawater intrusion.
4. How to define boundary condition in the landward side - how far
and what?
5. Any other useful tips for carrying out the above study.
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/
================================================
Back to top
Reply to sender | Reply to group | Reply via web post
Messages in this topic (3)
1.2.
Re: Model Setup for FEFLOW
Posted by: "little willow" little_willow71@... little_willow71
Mon Dec 11, 2006 12:15 pm
Hi Kumar,
-yes you can make trp file outside feflow. Just look
at the file format for trp file.
-if you have density of well for an area with average
pumping then you can 'simulate' them as well by
putting them as well boundaries. Of course having fix
coordinates is better
-you have to have a boundary taken from bigger
model(or assumption) for smaller part(nested model)
-be creative to define the boundary, it can be
topographic divide, groundwater divide, river
location, fixed head location or the worst but could
be better, assumption by considering good hydrogeologi
knowledge
-wait to hear from you
bye
LW
--- "C. P. Kumar" <cpkumar@...> wrote:
> Dear Group Members,
>
> Using FEFLOW (for the first time), I am in the
> process of model setup
> for simulation of seawater intrusion in Goa coast
> (India). The
> relevant details are briefly presented below.
>
> [A] Background for taking-up the Study:
>
> Coastal tracts of Goa (India) are rapidly being
> transformed into
> settlement areas. The poor water supply facilities
> has encouraged
> people to have their own source of water by digging
> wells. During the
> last decade, there have been large-scale withdrawals
> of groundwater
> by builders, hotels and other tourist
> establishments. Though the
> seawater intrusion has not yet assumed serious
> magnitude, but in the
> coming years it may turn to be a major problem if
> corrective measures
> are not initiated at this stage.
>
> [B] Objectives of the Study:
>
> Simulation of seawater intrusion in a region along
> Goa coast (Bardez
> taluk of North Goa); evaluation of the impact on
> seawater intrusion
> due to various groundwater pumping scenarios;
> sensitivity analysis;
> and suggestions for remedial measures.
>
> [C] Laboratory and Field Investigations carried out:
>
> * Identification of 20 observation wells;
> measurement of monthly
> groundwater level data in observation wells
> (September 2004 to August
> 2005); collection of bi-monthly groundwater samples
> during September
> 2004 to May 2005.
>
> * Based upon the bi-monthly measurements of salinity
> in laboratory,
> groundwater quality in all the observation wells was
> found to be
> reasonably fresh, both in pre- and post-monsoon
> periods. It can be
> attributed to the fact that the transition zone of
> fresh water-saline
> water lies below the shallow open wells (in shallow
> unconfined
> aquifer to a depth of about 10 - 12 m below ground),
> as evidenced by
> vertical electrical soundings.
>
> * Resistivity profiling: Apparent electrical
> resistivity measured
> along four profiles (at 10 m depth plane) from sea
> coast to 525
> meters inland. The seawater mixed zone was witnessed
> along two
> sections in the low lying sandy alluvial areas.
>
> * Vertical electrical sounding: Carried out at 7
> monitoring well
> locations upto a depth of 20 metres. Only three
> wells in the study
> area show low values of resistivity below 12 metres
> depth, indicating
> the presence of seawater or mixed zone below this
> depth.
>
> [D] Model Setup:
>
> The study area map (boundary - dxf, rivers - dxf,
> location of
> observation wells - pnt) has been digitized and an
> initial finite
> element mesh has been created for the entire area.
> Design of slices
> and layers (3D model) and flow and transport data
> (initials,
> boundaries, materials) are still to be done. There
> is mostly single
> aquifer system. In low lying areas, it is unconfined
> aquifer
> consisting of sandy loam (upto 15 m) over
> unfractured hard rock. In
> plateau areas, it is confined aquifer - laterite,
> clay and fractured
> hard rock.
>
> [E] MY QUERIES:
>
> 1. Many of the input data files for FEFLOW (initial
> distribution of
> hydraulic head and mass concentration, river water
> levels, well
> pumping rates, transmissivity, conductivity, aquifer
> top and bottom
> elevation etc.) are required to be in the trp
> (ASCII) format. How
> these input files are to be created? Whether FEFLOW
> itself allows
> creation of such files or some outside method is
> needed and how to do
> that?
>
> 2. There are large number of dugwells in the study
> area (reported
> density = 18 wells/km2, draft rate = 155 to 259
> m3/day). However,
> locations of these wells (on map) and their actual
> drafts are not
> available. In such case, how well drafts can be
> incorporated in the
> simulations?
>
> 3. How to proceed with FEFLOW setup if we intend
> simulation only in
> part of the study area, say upto around 2 to 3 km
> within the coast
> (15 km long), which is more vulnerable to seawater
> intrusion.
>
> 4. How to define boundary condition in the landward
> side - how far
> and what?
>
> 5. Any other useful tips for carrying out the above
> study.
>
> I shall be grateful for any suggestions from the
> learned members in
> this group.
>
> Thanks & Regards
> Kumar
>
> ================================================
> C. P. KUMAR
> Scientist 'E1'
> National Institute of Hydrology
> Jal Vigyan Bhawan
> Roorkee - 247667 (Uttaranchal)
> INDIA
>
> Web Page : http://www.angelfire.com/nh/cpkumar/
> ================================================
> Unfold the Goddess Within:
> http://groups.yahoo.com/group/Shambhavi/
> ================================================
Back to top
Reply to sender | Reply to group | Reply via web post
Messages in this topic (3)
1.3.
Re: Model Setup for FEFLOW
Posted by: "Bontemps Thierry" thierry.bontemps@... tbontemps
Mon Dec 11, 2006 3:02 pm
for your query on dug wells, if you attribute those wells to your first top
layer you can you use in flow material menu the "In/out flow on the top"
button. You have to do the balance between the pumping rate due to those
dugwells with infiltration rate (rain) and infiltration rate due to
irrigation(or other sources).
best regards
Thierry BONTEMPS
Project Manager - Civil & Environmental Technologies Dpt
TRACTEBEL DEVELOPMENT ENGINEERING S.A.
---------------------------------------------------
Avenue Jean Monnet 1 - B 1348 Louvain-la-Neuve - BELGIUM
tel. + 32 10 477 830 - fax + 32 10 477 819
mailto:thierry.bontemps@... <mailto:thierry.bontemps@tractebel
com>
www.tde.tractebel.com <http://www.tde.tractebel.com/>
________________________________
From: feflow@... [mailto:feflow@...] On Behalf
Of C. P. Kumar
Sent: lundi 11 décembre 2006 05:50
To: feflow@...
Subject: [feflow] Model Setup for FEFLOW
Dear Group Members,
Using FEFLOW (for the first time), I am in the process of model setup
for simulation of seawater intrusion in Goa coast (India). The
relevant details are briefly presented below.
[A] Background for taking-up the Study:
Coastal tracts of Goa (India) are rapidly being transformed into
settlement areas. The poor water supply facilities has encouraged
people to have their own source of water by digging wells. During the
last decade, there have been large-scale withdrawals of groundwater
by builders, hotels and other tourist establishments. Though the
seawater intrusion has not yet assumed serious magnitude, but in the
coming years it may turn to be a major problem if corrective measures
are not initiated at this stage.
[B] Objectives of the Study:
Simulation of seawater intrusion in a region along Goa coast (Bardez
taluk of North Goa); evaluation of the impact on seawater intrusion
due to various groundwater pumping scenarios; sensitivity analysis;
and suggestions for remedial measures.
[C] Laboratory and Field Investigations carried out:
* Identification of 20 observation wells; measurement of monthly
groundwater level data in observation wells (September 2004 to August
2005); collection of bi-monthly groundwater samples during September
2004 to May 2005.
* Based upon the bi-monthly measurements of salinity in laboratory,
groundwater quality in all the observation wells was found to be
reasonably fresh, both in pre- and post-monsoon periods. It can be
attributed to the fact that the transition zone of fresh water-saline
water lies below the shallow open wells (in shallow unconfined
aquifer to a depth of about 10 - 12 m below ground), as evidenced by
vertical electrical soundings.
* Resistivity profiling: Apparent electrical resistivity measured
along four profiles (at 10 m depth plane) from sea coast to 525
meters inland. The seawater mixed zone was witnessed along two
sections in the low lying sandy alluvial areas.
* Vertical electrical sounding: Carried out at 7 monitoring well
locations upto a depth of 20 metres. Only three wells in the study
area show low values of resistivity below 12 metres depth, indicating
the presence of seawater or mixed zone below this depth.
[D] Model Setup:
The study area map (boundary - dxf, rivers - dxf, location of
observation wells - pnt) has been digitized and an initial finite
element mesh has been created for the entire area. Design of slices
and layers (3D model) and flow and transport data (initials,
boundaries, materials) are still to be done. There is mostly single
aquifer system. In low lying areas, it is unconfined aquifer
consisting of sandy loam (upto 15 m) over unfractured hard rock. In
plateau areas, it is confined aquifer - laterite, clay and fractured
hard rock.
[E] MY QUERIES:
1. Many of the input data files for FEFLOW (initial distribution of
hydraulic head and mass concentration, river water levels, well
pumping rates, transmissivity, conductivity, aquifer top and bottom
elevation etc.) are required to be in the trp (ASCII) format. How
these input files are to be created? Whether FEFLOW itself allows
creation of such files or some outside method is needed and how to do
that?
2. There are large number of dugwells in the study area (reported
density = 18 wells/km2, draft rate = 155 to 259 m3/day). However,
locations of these wells (on map) and their actual drafts are not
available. In such case, how well drafts can be incorporated in the
simulations?
3. How to proceed with FEFLOW setup if we intend simulation only in
part of the study area, say upto around 2 to 3 km within the coast
(15 km long), which is more vulnerable to seawater intrusion.
4. How to define boundary condition in the landward side - how far
and what?
5. Any other useful tips for carrying out the above study.
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/ <http://www.angelfire
com/nh/cpkumar/>
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/ <http://groups.yahoo
com/group/Shambhavi/>
================================================
for your query on dug wells, if you attribute those wells to your first top
layer you can you use in flow material menu the "In/out flow on the top" button.
You have to do the balance between the pumping rate due to those dugwells with
infiltration rate (rain) and infiltration rate due to irrigation(or other
sources).
best regards
Thierry BONTEMPS
Project Manager - Civil & Environmental Technologies Dpt
TRACTEBEL DEVELOPMENT ENGINEERING S.A.
---------------------------------------------------
Avenue Jean Monnet 1 - B 1348 Louvain-la-Neuve - BELGIUM
tel. + 32 10 477 830 - fax + 32 10 477 819
mailto:thierry.bontemps@... <mailto:thierry.bontemps@...>
www.tde.tractebel.com <http://www.tde.tractebel.com/>
________________________________
From: feflow@... [mailto:feflow@...] On Behalf Of C.
P. Kumar
Sent: lundi 11 décembre 2006 05:50
To: feflow@...
Subject: [feflow] Model Setup for FEFLOW
Dear Group Members,
Using FEFLOW (for the first time), I am in the process of model setup
for simulation of seawater intrusion in Goa coast (India). The
relevant details are briefly presented below.
[A] Background for taking-up the Study:
Coastal tracts of Goa (India) are rapidly being transformed into
settlement areas. The poor water supply facilities has encouraged
people to have their own source of water by digging wells. During the
last decade, there have been large-scale withdrawals of groundwater
by builders, hotels and other tourist establishments. Though the
seawater intrusion has not yet assumed serious magnitude, but in the
coming years it may turn to be a major problem if corrective measures
are not initiated at this stage.
[B] Objectives of the Study:
Simulation of seawater intrusion in a region along Goa coast (Bardez
taluk of North Goa); evaluation of the impact on seawater intrusion
due to various groundwater pumping scenarios; sensitivity analysis;
and suggestions for remedial measures.
[C] Laboratory and Field Investigations carried out:
* Identification of 20 observation wells; measurement of monthly
groundwater level data in observation wells (September 2004 to August
2005); collection of bi-monthly groundwater samples during September
2004 to May 2005.
* Based upon the bi-monthly measurements of salinity in laboratory,
groundwater quality in all the observation wells was found to be
reasonably fresh, both in pre- and post-monsoon periods. It can be
attributed to the fact that the transition zone of fresh water-saline
water lies below the shallow open wells (in shallow unconfined
aquifer to a depth of about 10 - 12 m below ground), as evidenced by
vertical electrical soundings.
* Resistivity profiling: Apparent electrical resistivity measured
along four profiles (at 10 m depth plane) from sea coast to 525
meters inland. The seawater mixed zone was witnessed along two
sections in the low lying sandy alluvial areas.
* Vertical electrical sounding: Carried out at 7 monitoring well
locations upto a depth of 20 metres. Only three wells in the study
area show low values of resistivity below 12 metres depth, indicating
the presence of seawater or mixed zone below this depth.
[D] Model Setup:
The study area map (boundary - dxf, rivers - dxf, location of
observation wells - pnt) has been digitized and an initial finite
element mesh has been created for the entire area. Design of slices
and layers (3D model) and flow and transport data (initials,
boundaries, materials) are still to be done. There is mostly single
aquifer system. In low lying areas, it is unconfined aquifer
consisting of sandy loam (upto 15 m) over unfractured hard rock. In
plateau areas, it is confined aquifer - laterite, clay and fractured
hard rock.
[E] MY QUERIES:
1. Many of the input data files for FEFLOW (initial distribution of
hydraulic head and mass concentration, river water levels, well
pumping rates, transmissivity, conductivity, aquifer top and bottom
elevation etc.) are required to be in the trp (ASCII) format. How
these input files are to be created? Whether FEFLOW itself allows
creation of such files or some outside method is needed and how to do
that?
2. There are large number of dugwells in the study area (reported
density = 18 wells/km2, draft rate = 155 to 259 m3/day). However,
locations of these wells (on map) and their actual drafts are not
available. In such case, how well drafts can be incorporated in the
simulations?
3. How to proceed with FEFLOW setup if we intend simulation only in
part of the study area, say upto around 2 to 3 km within the coast
(15 km long), which is more vulnerable to seawater intrusion.
4. How to define boundary condition in the landward side - how far
and what?
5. Any other useful tips for carrying out the above study.
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
<http://www.angelfire.com/nh/cpkumar/>
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/
<http://groups.yahoo.com/group/Shambhavi/>
================================================
Hi Kumar,
-yes you can make trp file outside feflow. Just look
at the file format for trp file.
-if you have density of well for an area with average
pumping then you can 'simulate' them as well by
putting them as well boundaries. Of course having fix
coordinates is better
-you have to have a boundary taken from bigger
model(or assumption) for smaller part(nested model)
-be creative to define the boundary, it can be
topographic divide, groundwater divide, river
location, fixed head location or the worst but could
be better, assumption by considering good hydrogeologi
knowledge
-wait to hear from you
bye
LW
--- "C. P. Kumar" <cpkumar@...> wrote:
> Dear Group Members,
>
> Using FEFLOW (for the first time), I am in the
> process of model setup
> for simulation of seawater intrusion in Goa coast
> (India). The
> relevant details are briefly presented below.
>
> [A] Background for taking-up the Study:
>
> Coastal tracts of Goa (India) are rapidly being
> transformed into
> settlement areas. The poor water supply facilities
> has encouraged
> people to have their own source of water by digging
> wells. During the
> last decade, there have been large-scale withdrawals
> of groundwater
> by builders, hotels and other tourist
> establishments. Though the
> seawater intrusion has not yet assumed serious
> magnitude, but in the
> coming years it may turn to be a major problem if
> corrective measures
> are not initiated at this stage.
>
> [B] Objectives of the Study:
>
> Simulation of seawater intrusion in a region along
> Goa coast (Bardez
> taluk of North Goa); evaluation of the impact on
> seawater intrusion
> due to various groundwater pumping scenarios;
> sensitivity analysis;
> and suggestions for remedial measures.
>
> [C] Laboratory and Field Investigations carried out:
>
> * Identification of 20 observation wells;
> measurement of monthly
> groundwater level data in observation wells
> (September 2004 to August
> 2005); collection of bi-monthly groundwater samples
> during September
> 2004 to May 2005.
>
> * Based upon the bi-monthly measurements of salinity
> in laboratory,
> groundwater quality in all the observation wells was
> found to be
> reasonably fresh, both in pre- and post-monsoon
> periods. It can be
> attributed to the fact that the transition zone of
> fresh water-saline
> water lies below the shallow open wells (in shallow
> unconfined
> aquifer to a depth of about 10 - 12 m below ground),
> as evidenced by
> vertical electrical soundings.
>
> * Resistivity profiling: Apparent electrical
> resistivity measured
> along four profiles (at 10 m depth plane) from sea
> coast to 525
> meters inland. The seawater mixed zone was witnessed
> along two
> sections in the low lying sandy alluvial areas.
>
> * Vertical electrical sounding: Carried out at 7
> monitoring well
> locations upto a depth of 20 metres. Only three
> wells in the study
> area show low values of resistivity below 12 metres
> depth, indicating
> the presence of seawater or mixed zone below this
> depth.
>
> [D] Model Setup:
>
> The study area map (boundary - dxf, rivers - dxf,
> location of
> observation wells - pnt) has been digitized and an
> initial finite
> element mesh has been created for the entire area.
> Design of slices
> and layers (3D model) and flow and transport data
> (initials,
> boundaries, materials) are still to be done. There
> is mostly single
> aquifer system. In low lying areas, it is unconfined
> aquifer
> consisting of sandy loam (upto 15 m) over
> unfractured hard rock. In
> plateau areas, it is confined aquifer - laterite,
> clay and fractured
> hard rock.
>
> [E] MY QUERIES:
>
> 1. Many of the input data files for FEFLOW (initial
> distribution of
> hydraulic head and mass concentration, river water
> levels, well
> pumping rates, transmissivity, conductivity, aquifer
> top and bottom
> elevation etc.) are required to be in the trp
> (ASCII) format. How
> these input files are to be created? Whether FEFLOW
> itself allows
> creation of such files or some outside method is
> needed and how to do
> that?
>
> 2. There are large number of dugwells in the study
> area (reported
> density = 18 wells/km2, draft rate = 155 to 259
> m3/day). However,
> locations of these wells (on map) and their actual
> drafts are not
> available. In such case, how well drafts can be
> incorporated in the
> simulations?
>
> 3. How to proceed with FEFLOW setup if we intend
> simulation only in
> part of the study area, say upto around 2 to 3 km
> within the coast
> (15 km long), which is more vulnerable to seawater
> intrusion.
>
> 4. How to define boundary condition in the landward
> side - how far
> and what?
>
> 5. Any other useful tips for carrying out the above
> study.
>
> I shall be grateful for any suggestions from the
> learned members in
> this group.
>
> Thanks & Regards
> Kumar
>
> ================================================
> C. P. KUMAR
> Scientist 'E1'
> National Institute of Hydrology
> Jal Vigyan Bhawan
> Roorkee - 247667 (Uttaranchal)
> INDIA
>
> Web Page : http://www.angelfire.com/nh/cpkumar/
> ================================================
> Unfold the Goddess Within:
> http://groups.yahoo.com/group/Shambhavi/
> ================================================
Dear Group Members,
Using FEFLOW (for the first time), I am in the process of model setup
for simulation of seawater intrusion in Goa coast (India). The
relevant details are briefly presented below.
[A] Background for taking-up the Study:
Coastal tracts of Goa (India) are rapidly being transformed into
settlement areas. The poor water supply facilities has encouraged
people to have their own source of water by digging wells. During the
last decade, there have been large-scale withdrawals of groundwater
by builders, hotels and other tourist establishments. Though the
seawater intrusion has not yet assumed serious magnitude, but in the
coming years it may turn to be a major problem if corrective measures
are not initiated at this stage.
[B] Objectives of the Study:
Simulation of seawater intrusion in a region along Goa coast (Bardez
taluk of North Goa); evaluation of the impact on seawater intrusion
due to various groundwater pumping scenarios; sensitivity analysis;
and suggestions for remedial measures.
[C] Laboratory and Field Investigations carried out:
* Identification of 20 observation wells; measurement of monthly
groundwater level data in observation wells (September 2004 to August
2005); collection of bi-monthly groundwater samples during September
2004 to May 2005.
* Based upon the bi-monthly measurements of salinity in laboratory,
groundwater quality in all the observation wells was found to be
reasonably fresh, both in pre- and post-monsoon periods. It can be
attributed to the fact that the transition zone of fresh water-saline
water lies below the shallow open wells (in shallow unconfined
aquifer to a depth of about 10 - 12 m below ground), as evidenced by
vertical electrical soundings.
* Resistivity profiling: Apparent electrical resistivity measured
along four profiles (at 10 m depth plane) from sea coast to 525
meters inland. The seawater mixed zone was witnessed along two
sections in the low lying sandy alluvial areas.
* Vertical electrical sounding: Carried out at 7 monitoring well
locations upto a depth of 20 metres. Only three wells in the study
area show low values of resistivity below 12 metres depth, indicating
the presence of seawater or mixed zone below this depth.
[D] Model Setup:
The study area map (boundary - dxf, rivers - dxf, location of
observation wells - pnt) has been digitized and an initial finite
element mesh has been created for the entire area. Design of slices
and layers (3D model) and flow and transport data (initials,
boundaries, materials) are still to be done. There is mostly single
aquifer system. In low lying areas, it is unconfined aquifer
consisting of sandy loam (upto 15 m) over unfractured hard rock. In
plateau areas, it is confined aquifer - laterite, clay and fractured
hard rock.
[E] MY QUERIES:
1. Many of the input data files for FEFLOW (initial distribution of
hydraulic head and mass concentration, river water levels, well
pumping rates, transmissivity, conductivity, aquifer top and bottom
elevation etc.) are required to be in the trp (ASCII) format. How
these input files are to be created? Whether FEFLOW itself allows
creation of such files or some outside method is needed and how to do
that?
2. There are large number of dugwells in the study area (reported
density = 18 wells/km2, draft rate = 155 to 259 m3/day). However,
locations of these wells (on map) and their actual drafts are not
available. In such case, how well drafts can be incorporated in the
simulations?
3. How to proceed with FEFLOW setup if we intend simulation only in
part of the study area, say upto around 2 to 3 km within the coast
(15 km long), which is more vulnerable to seawater intrusion.
4. How to define boundary condition in the landward side - how far
and what?
5. Any other useful tips for carrying out the above study.
I shall be grateful for any suggestions from the learned members in
this group.
Thanks & Regards
Kumar
================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
================================================
Unfold the Goddess Within:
http://groups.yahoo.com/group/Shambhavi/
================================================
This is a brief email to provide information on the upcoming model
calibration and uncertainty analysis course – using PEST – in late summer
2006.
Regards – Matt Tonkin
pest@... <mailto:pest@...>
Calibration and Predictive Uncertainty Analysis Using PEST, San Francisco,
Fall, 2006
In collaboration with the Groundwater Resources Association of California
(GRA) the third annual California PEST Course will be presented at the Savoy
Hotel in San Francisco, September 13th to 15th, 2006. The instructors will
be Dr. John Doherty, the author of PEST, and Matt Tonkin.
For more details visit http://www.sspa.com/PEST/training.html
<http://www.sspa.com/PEST/training.html> or to register for the course,
visit http://www.grac.org/pest.html <http://www.grac.org/pest.html> .
Further info about PEST can be found at pest@... <mailto:pest@...>
. This account is used to circulate occasional information on courses and
software updates. PEST has been freeware since February 2001 and is
available at http://www.sspa.com/PEST <http://www.sspa.com/PEST> .
[Non-text portions of this message have been removed]
Hy,
I'm just begeening to use Feflow 5.2. I'm building a model in 3D with
8 superelements, corresponding to 8 different conductivity zones.
During the genertation of my finite element mesh (FEM) it appears an
error:....process abort on superlement no 8.....or somethings like
that. When I remove this superelement, feflow generate my FEM correctly.
Someone know the reason why Feflow abort is FEM generation on
superelement no 8. I must indicate that there is many nodes on each
superlement borders. In fact, the borders of my superelements
corresponding to rivers imported from a GIS. This tivers contain many
node and I simply digitize over the lines of the rivers.
Thanks a lot,
Dear Sir/Madam
I would like to prepare the input files of Modflow (PM5.1)
externally (by another application). The input files are
*.con,*.htc,*.lea and so on.
It's done now, but a problem has occured. In short, Modflow doesn't
look at my input files - bas.dat, bcf.dat and etc. I found out that
I should "regenerate input files" before running modflow.
This may be done by ticking the relative checkbox in run dialog,
while running modflow manually.
1- Is there any way to enforce Modflow to regenerate input files
automatically? (a switch, a preferences or ...)
2- If not, what are the format of these files. (Fortunately they are
text files).
Sincerely,
Last call! - spaces are still available for two parameter estimation and
uncertainty analysis course to be held in the UK and USA this summer.
Best wishes,
Matt Tonkin, SSP&A
matt@...
Courses: Model Calibration and Predictive Uncertainty using PEST
Shrewsbury, England, September 13-15, 2005
Stony Brook, Long Island, NY, September 19-21, 2005 (near MacArthur Airport
and Port Jefferson)
Principal Instructor: Dr. John Doherty (author of PEST)
Guest Instructor: Jim Rumbaugh (author of Groundwater Vistas) (New
York course only)
Assistant Instructor: Matt Tonkin
This intensive course instructs participants on the automated calibration of
environmental models, and the analysis of the predictive uncertainty
associated with such models. The principal instructor is the developer of
PEST, the industry standard package for model-independent, automated
calibration and predictive uncertainty analysis. The course focuses on the
use of PEST, including the new capabilities added to Versions 8 and 9 this
year. The course includes thorough coverage of the theory and application of
nonlinear parameter estimation techniques in the calibration of different
types of models. There is a strong practical aspect of the course -
participants gain hands-on experience in the use of PEST, including its
advanced regularization and predictive analysis features, in the calibration
of groundwater flow and transport models, surface water quality and quantity
models, as well as other types of models including a vadose zone model and a
biological growth model.
Course Details and Registration
For detailed information on course content visit
www.sspa.com/pest/training.html to download a prospectus, or write to
pest@....
To register on-line for the New York course please visit
www.sspa.com/pest/training.html
To register on-line for the UK course please visit
http://www.esinternational.com/training/CourseDetail.asp?course_id=49
Information about PEST can be found at pest@.... This account was
established for PEST users to obtain information on courses and software
updates. The account is used to circulate occasional information. To be
added to the PEST list write to pest@... with the subject "subscribe".
First International FEFLOW User Conference
WASY is organising "International FEFLOW User
Conference" during September 10-15, 2006 at Berlin,
Germany. The aim is to provide an international
platform to present FEFLOW-related work, to meet other
users of the leading groundwater modeling software and
to share the latest developments.
Conference Topics
Topic 1: Recent Developments in Finite Element
Groundwater Modeling
FEM, Fast Solvers, Mesh Generation, Parallel
Computing, Nonlinear Problems
Topic 2: Software Technology
Interfaces, GIS, 3D Graphics
Topic 3: Applications
Large Models, Model Coupling, Calibration and
Parameter Estimation, Reactive Multi-Species
Transport, Heat Transport, Reliability of Modeling,
New Fields
Call for Papers
Abstracts may be submitted to the Organizing Committee
before December 1st, 2005. Please email your abstract
(up to 300 words) in Microsoft Word format to
feflow2006@..., including information about
author(s), organization(s), email address(es) and
whether oral or poster presentation is preferred.
Conference details are available at
http://feflow2006.feflow.de/
Regards
Kumar
==================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
==================================================
Hydrology Resources on the Web:
http://www.angelfire.com/nh/cpkumar/forums.html
Kumar Links to Hydrology Resources:
http://www.angelfire.com/nh/cpkumar/hydrology.html
Google Groups in Hydrology:
http://www.angelfire.com/bc/nihhrrc/google.html
Software User Groups in Groundwater Modelling:
http://www.angelfire.com/bc/nihhrrc/groups.html
==================================================
____________________________________________________
Start your day with Yahoo! - make it your home page
http://www.yahoo.com/r/hs
Please find below an announcement for the release of V10 of PEST and
associated UK and USA courses in parameter estimation and uncertainty
analysis.
Apologies for any double postings, best wishes,
Matt Tonkin, SSP&A, matt@...
PEST Version 10 Beta Release
PEST v10 will be released later this year. A beta version can be downloaded
from ( http://www.sspa.com/pest/download.html) for those interested in
exploring recent developments in model predictive uncertainty analysis.
Enhancements to the capabilities of PEST in v10 include:
* PEST’s SVD-assist scheme has been enhanced, enabling regularized inversion
to be used with highly parameterized models with efficiencies commensurate
with traditional parameter estimation.
* PEST’s predictive analyser is more powerful, with an improved line-search
algorithm and added functionality to encompass the effects of predictive
noise on predictive variability.
* A greatly expanded suite of utility software supports:
* Comprehensive post-processing of PEST results including analysis and
plotting of the resolution matrix and other by-products of the regularized
inversion process.
* Quantification of the contribution to pre- and/or post-calibration error
variance of important model predictions by individual parameters or
different parameter types.
* Data acquisition analysis - assess the value of making extra measurements
of system state (e.g., water level) or of system properties (e.g.,
transmissivity) in terms of predictive error variance reduction, in advance
of acquiring those data.
Moore and Doherty (Water Resources Research, May 2005) show that traditional
predictive uncertainty analyses can underestimate true variability by
neglecting complexity that it is beyond the ability of the calibration
process to capture. PEST Version 10 provides access to the methodologies
presented in that paper that support the analysis of predictive error
variance as an adjunct to regularized inversion.
Courses: Places are still available at the upcoming PEST courses in the UK
and USA
Principal Instructor: Dr. John Doherty (author of PEST)
Guest Instructor: Jim Rumbaugh (author of Groundwater Vistas) (NY
course only)
Assistant Instructor: Matt Tonkin (SSPA)
For more information on the courses visit:
http://www.sspa.com/pest/training.html
To register on-line for the UK course visit:
http://www.esinternational.com/training/CourseDetail.asp?course_id=49
To register on-line for the NY course visit:
www.sspa.com/pest/training.html
Information about PEST plus technical support can be found by writing to
pest@... <mailto:pest@...> . This account was established for PEST
users to obtain information on courses and software updates. The account is
used to circulate occasional information. To be added to this list write to
pest@... with "subscribe" as the subject. To ensure you receive no
future emails write to pest@... with “unsubscribe” as the subject.
[Non-text portions of this message have been removed]
hi ,
i am ganesh ( Chennai, India ) working in FEFLOW 5.1
version . i have one doubt in this, while giving the
Temporal data, the final time menu was hidden. Could
anybody pls tell to me why it appears like this .
Thanks in advance
yours truly,
ganesh
--- fabys@... wrote:
> hi,
> i am Faby. Recently we have procured the FEFLOW
> program
> i would like to know if anyone in India (especially
> Mumbai) has hands on
> experience in using FEFLOW
> thankx
> faby
>
> Quoting feflow Moderator
> <feflow-owner@...>:
>
> >
> >
> > Hello,
> >
> > Welcome to the feflow group at Yahoo! Groups, a
> > free, easy-to-use email group service. Please
> > take a moment to review this message.
> >
> > To start sending messages to members of this
> group,
> > simply send email to
> >
> > feflow@...
> >
> > If you do not wish to belong to feflow, you may
> > unsubscribe by sending an email to
> >
> > feflow-unsubscribe@...
> >
> > You may also visit the Yahoo! Groups web site to
> modify your
> > subscriptions:
> >
> > http://in.groups.yahoo.com/mygroups
> >
> >
> > Regards,
> >
> > Moderator, feflow
> >
> >
> >
> > Complete your Yahoo! Groups account:
> >
>
----------------------------------------------------------------------
> > Your email address has been added to the email
> list of a Yahoo! Group.
> > To gain access to all of your group's web features
> (previous messages,
> > photos, files, calendar, etc.) and easier control
> of your message
> > delivery options, we highly recommend that you
> complete your account
> > by connecting your email address to Yahoo account.
> It is easy and free.
> > Please visit:
> > http://in.groups.yahoo.com/convacct?email=fabys%
> 40apsara.barc.ernet.in&list=feflow
> >
> > Your use of Yahoo! Groups is subject to
> http://in.docs.yahoo.com/info/terms/
> >
> >
> >
> >
> >
> >
> >
> >
>
>
>
>
> -------------------------------------------------
>
>
__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com
hi,
i am Faby. Recently we have procured the FEFLOW program
i would like to know if anyone in India (especially Mumbai) has hands on
experience in using FEFLOW
thankx
faby
Quoting feflow Moderator <feflow-owner@...>:
>
>
> Hello,
>
> Welcome to the feflow group at Yahoo! Groups, a
> free, easy-to-use email group service. Please
> take a moment to review this message.
>
> To start sending messages to members of this group,
> simply send email to
>
> feflow@...
>
> If you do not wish to belong to feflow, you may
> unsubscribe by sending an email to
>
> feflow-unsubscribe@...
>
> You may also visit the Yahoo! Groups web site to modify your
> subscriptions:
>
> http://in.groups.yahoo.com/mygroups
>
>
> Regards,
>
> Moderator, feflow
>
>
>
> Complete your Yahoo! Groups account:
> ----------------------------------------------------------------------
> Your email address has been added to the email list of a Yahoo! Group.
> To gain access to all of your group's web features (previous messages,
> photos, files, calendar, etc.) and easier control of your message
> delivery options, we highly recommend that you complete your account
> by connecting your email address to Yahoo account. It is easy and free.
> Please visit:
> http://in.groups.yahoo.com/convacct?email=fabys%
40apsara.barc.ernet.in&list=feflow
>
> Your use of Yahoo! Groups is subject to http://in.docs.yahoo.com/info/terms/
>
>
>
>
>
>
>
>
-------------------------------------------------
INTERNATIONAL GROUNDWATER CONFERENCE
on Groundwater (Perspectives, Problems and Challenges)
IGC - 2006, New Delhi, February 1-4, 2006
Organized by School of Environmental Sciences, JNU,
New Delhi-110067 in collaboration with
Department of Civil Engineering, Indian Institute of
Technology, New Delhi-110016 & KTH, Stockholm, Sweden
Themes for IGC-2006
TS-1 Water Resources Assessment
TS-2 Recharge Process and Artificial Recharge
TS-3 Water and Environment
TS-4 Models and its application in soft and hard rock
aquifer system
TS-5 Management Aspects of Groundwater
Call for Papers
All abstracts (not exceeding 250 words on a 3.5"
floppy or CD along with a hard copy in duplicate)
should reach Dr. AL Ramanathan, Organizing Secretary,
Conference Secretariat (IGC-2006), School of
Environmental Sciences, JNU, New Delhi-110067 on or
before 15th June, 2005. Acceptance will be
communicated by July 11, 2005. Authors will have to
submit full manuscript of the paper(s) (with original
figures, if any) to the Conference Secretariat by
October 10, 2005. Necessary instructions regarding
preparation of the manuscript(s) will be sent along
with the acceptance and author(s) are requested to
submit the final text in electronic form (CD or 3.5"
floppy).
Please contact for further details:
Dr. AL. Ramanathan
Conference Organizing Secretary (IGC-2006),
School of Environmental Sciences, JNU,
New Delhi-110067, India
+91 (0) 11-26704314 or 26704316
+91 (0) 11-26106501
alr_jnu@..., alrjnu@...
Dr.M. Thangarajan
Conference Chairman (IGC-2006),
NGRI, Hyderabad
+91-040-23434698 (O),
+91-040-27175156 (R)
mthangarajan@..., or
mthangarajan@...
Dr. A.K. Keshari
Conference Co-organizing Secretary,
IIT, New Delhi
akeshari@...,
akeshari@...,
Dr. Prosun Bhattacharya
Conference Co-organising Secretary,
KTH, Sweden
prosun@...
Web: www.jnu.ac.in; www.envisjnu.net
__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com
Dear Friend,
I have been compiling selected extracts on groundwater
modelling discussion from various mailing lists for
past few months, as given below. I understand that in
view of random and discontinuous placing, many parts
may not be easily comprehensible. Still I think that
it could be helpful to groundwater modellers to some
extent.
Regards
Kumar
==================================================
C. P. KUMAR
Scientist 'E1'
National Institute of Hydrology
Jal Vigyan Bhawan
Roorkee - 247667 (Uttaranchal)
INDIA
Web Page : http://www.angelfire.com/nh/cpkumar/
==================================================
Kumar Links to Hydrology Resources:
http://www.angelfire.com/nh/cpkumar/hydrology.html
Google Groups in Hydrology:
http://www.angelfire.com/bc/nihhrrc/google.html
Software User Groups in Groundwater Modelling:
http://www.angelfire.com/bc/nihhrrc/groups.html
==================================================
-----------------------------------------------------------------
* In my experience, PCG is faster than LMG for small
models but LMG is faster for large models. Of course,
for small models, speed generally is not so much of an
issue.
* DAMP is used as a multiplier to scale the head
change at each iteration, not RELAX. The DAMP
parameter in the PCG solver package is analogous to
the ACCL parameter in the SIP package. Although I
cannot explain precisely what RELAX controls (since
I'm no mathematician), the typical range for RELAX is
0.97 to 1.0. In my experience, setting RELAX=0.97 can
help to achieve convergence, and may speed up
convergence on a "well-behaved" model, but not always.
* I'm sure you've heard "All models are wrong but some
are useful." If you replaced all the wells in a model
with drains, you would expect to get different
results. How is this any different? You have
replaced one package with a different one that is
based on different assumptions so of course, they get
different results. If you want to know which one is
better, examine the assumptions behind the different
packages and see which assumpptions best match the
conditions at the particular region to be modelled.
If none of the available packages do what you need,
write your own package to do what you need.
* The newer LPF package is the way that most other
models work, i.e., you enter Kz and the inter-cell
conductances are computed internally. The way that
MODFLOW88/96 did it with a pre-computed vertical
conductance always struck me as a bit odd; however,
that has been our happy MODFLOW world for about 20
years. So now we have a new option that is
mathematically more correct, but it is still
disconcerting when the computed heads are different.
I guess you'd have to ask a lawyer about who would
win. My sense is that the differences could never be
explained to a jury. It does present the MODFLOW
modeling community with a problem, though. The way
that you did it with MODFLOW-SURFACT is probably the
way that the USGS should have done it as well - adding
the input of Kz in the BCF Package.
* Input of vertical hydraulic conductivity has its
advantages, however, McDonald and Harbaugh got it
correct in keeping a fixed thickness of a cell for the
vertical direction conductance - for
gravity-segregated vertical equilibrium (GSVE), you
have a transmissivity that is conductivity times
saturated thickness which is valid only for the
horizontal direction and not for the vertical
direction (in actuality, the vertical direction
physics changes from GSVE to unsaturated flow which
would lower the conductivity further and that would be
closer to the "fixed thickness" answers that do not
reduce separation distance between 2 cells vertically
even for consideration of a homogeneous case, but that
aside). Nor does the document state where or under
what conditions the use of a "variable thickness for
vertical conductances" option performs better. That's
why I was asking to see if anyone knew why this was
done in the first place.
* I propose that the node location of a cell that
contains the water table should be located at the
water table instead of the center of the cell as is
standard. Comparisons of this formulation to analytic
calculations numerically implemented in the WATQ code
indicate a much improved solution at shallow depths
compared to the calculations of the current LPF
formulation. This formulation does not, however, take
into account the dynamics of drainage from the
unsaturated region above the water table which can be
a major influence. I want to repeat Richard Winston's
point that "All models are wrong". A model is not
intrinsically good or bad. That judgment depends on
what the model is used for. What may be better in one
situation may not be better in another. You have
highlighted this concept in your discussion of GSVE.
MODFLOW still exists for two contradictory reasons; 1)
as the name implies it is modular and hence easily
extensible to specialized situations. 2) It is widely
known and accepted that the code has accurately solved
groundwater flow problems. It is incorrect to extend
the second point to expect MODFLOW to accurately solve
all groundwater flow problems. Once again required
accuracy like good and bad depends on the problem that
needs to be solved. That MODFLOW produces two results
for the same geometry and boundary conditions means
that it approximates the physics of the flow situation
differently. It proper care is taken, the ability to
change the approximation of the physics of flow is a
good thing because the code can be tailored to
specific problems.
* Yes, having flexibility in averaging schemes is a
good thing. The LPF package provides one more
averaging scheme in the vertical direction. It does a
harmonic average of the conductances, as opposed to
the BCF package's harmonic average of vertical
conductivity times area divided by separation distance
as provided in the MODFLOW documentation for the
various fully three-dimensional, and
quasi-three-dimensional alternatives. However, I am
guessing that people are encountering drastically
different and surprising or unexpected results is
because of the vertical direction treatment.
Specifically, the cell thickness varies as a function
of its saturated thickness in the LPF package for
vertical direction treatment. For a simple example,
consider a homogeneous case with two cells where the
cell below is getting drier. The vertical conductance
quickly rises due to the cell below drying up, to such
levels that drain and dry up the cell above (which
also causes the conductance to increase in a cascading
manner) which would be a very different result than
with use of any of MODFLOW's BCF options. Like I
stated earlier, infact, when things dry up, it should
slow down the conductance due to physics change to
unsaturated flow, and even a gravity flow assumption
will not speed it up.
Yes, there is a dilema in GSVE models for vertical
direction treatment because GSVE by its definition,
applies only to horizontal direction flow - I have
seen this in saltwater-freshwater GSVE models with
multiple aquifers as well. And there too, when you
give it specialized treatment, it is due to certain
physically motivated considerations. Otherwise, the
way MODFLOW BCF did it (or a use of grid-block cell
thickness in the LPF package) is the best you can do
with the VE assumptions being used, since conductance
may be smaller than saturated levels due to
unsaturated zone physics - but you don't know by how
much, unless you simulate unsaturated zone physics.
Using saturated thickness instead of cell thickness in
the vertical direction leads to results that are more
removed from this physics.
* This is one of the most challenging groundwater
modelling projects you can find in real-world
modelling... Ideally, you should use a
saturated-unsaturated code, such as FEFLOW or Modflow
surfact or similar. Such codes are able of simulating
perched water conditions.
If you are using traditional MODFLOW, and assuming
saturated conditions, it is a bit more complicated to
simulate such a scenario. You will probably have some
dry cell issues (and perhaps some convergence
problems), but it is possible to simulate the open pit
crossing multiple layers using drain boundary
conditions.
For the upper layers, where seepage faces may occur,
set the drain elevation slightly above the layer
bottom elevation (say 0.1 m above cell bottom
elevation). If you use Visual MODFLOW as the
interface, that's very easy to do using formulas that
will assign the correct elevation even in irregular
layers. In that case, if the head in the pit wall is
higher than the cell bottom elevation, Modflow's drain
package will remove the outcroppng groundwater. The
conductance value (another input to the drain package)
is tipically a calibration parameter, obtained through
matching drain removal rates with real values observed
at the mine site.
I suggest that you also use a solver that is not too
aggressive, such as PCG2, and that you play a bit with
re-wetting parameters and dumping factors until you
obtain a stable solution. We've done several mine
dewatering modelling projects using this approach and
it definetely works for most cases, as long as you
understand the code and it's limitations.
* Dry cells in a multi-layer model are not necessarily
a bad thing unless they do not accurately reflect the
conditions in the field. Perhaps I am stating the
obvious, but just for the record, dry cells occur in
MODFLOW models when the calculated water table is
below the bottom elevation of the grid cell. Since
MODFLOW only simulates saturated groundwater flow, it
does not represent a head value in the unsaturated
cell, so the cell becomes 'dry' and MODFLOW assigns a
'dummy' head value usually in the range of -1e-30 (or
something else easily recognized as a dry cell).
Although the presence of dry cells in a model is often
a hassle because they create problems with the
convergence of the numerical solution, dry cells do
not necessarily indicate a 'problem' or error with the
model. In your case, the dry cells don't appear to be
causing a problem with the solution convergence (or
atleast, you haven't mentioned this problem) and you
are getting a good mass balance, which is a good sign
but doesn't necessarily indicate 'correctness' of the
solution. If the water levels in the second layer of
your model match closely with the observed field
conditions, then the occurance of dry cells in layer 1
appear to be reasonable.
However, if the dry cells are occurring where you
would otherwise expect saturated conditions (based on
water levels in the field) then you probably need to
revisit your boundary conditions to make sure they are
reasonable (conductance values are often the culprit),
check your initial heads and make sure you are not
starting the iterations with dry cells, and make sure
you have enough recharge flux entering the system to
accommodate flux leaving the system through wells,
rivers, and other boundary conditions. If all this
looks good, then Mark Wilsanac gave some very good
suggestions on how to change the solver and rewetting
package settings in order to deal with dry cells. -
Patrick Delaney
* If the river boundary cells are the only place in
your model where water may leave the system, then one
of the most likely causes of the mass balance problem
is the conductance values you are using for the river
cells. Check your conductance values to make sure
they are within reason. The conductance values can be
reasonably estimated using the following formula:
C = (L x W x Kv)/B
where
L = length of the river in a cell W = width of the
river in a cell Kv = vertical hydraulic conductivity
of the riverbed in a cell B = thickness of the
riverbed in a cell
Most of the popular graphical interfaces for MODFLOW
allow you to enter these 'physical' parameters and
will automatically calculate the conductance values
for each river boundary cell.
Another possible cause for mass balance problems could
be the solver you are using (SIP often produces larger
mass balance than other solvers like the PCG or LMG)
or perhaps the convergence criteria for the solver is
not 'tight enough'.
Just as an afterthought, the fact that you have more
water entering the system from the rivers than leaving
the system through the rivers does not, in itself,
indicate a problem with the water balance. This
indicates you have 'losing rivers' because the water
table adjacent to the river is lower than the river
stage. The excess water entering the system from the
rivers may be leaving through other avenues such as
evapotranspiration, pumping wells, drains, specified
head head boundaries, etc. - Patrick Delaney
* Check out if you dont have any dry well cells, or
any other dry boundary cell. If a cell goes dry during
simulation, it becomes inactive for MODFLOW, and any
boundary assigned to that dry cell will be ignored.
That means that your wells may be inactive (even
though you assigned them to be pumping all the time).
That typically produces a noticeble change in the
budget, but sometimes the heads may not change too
much, unless you look at specific well cells very
closely.
My suggestion is to first look into the budget for
changes in well pumping/injection rates. If the total
rate is different from those you entered into the
model, then you have a dry well cell. Zoom in all well
cells to identify which ones have become dry during
that stress period (look in all model layers).
* With a model set up with cell-to-cell size changes
below 50%, there can be instabilities or failure to
converge. This can be due to other reasons, or cell
size change coupled to highly variable conditions in a
transient solution. If a geologic unit pinches out,
that should be represented primarily by changes to
cell properties, and secondarily by changes in cell
dimension (aspect-ratio rules apply vertically as well
as horizontally). Remember to preserve aspect ratios
of each cell below 10:1, and below 5:1 to be safe. It
is acceptable to have a layer with variable properties
from cell-to-cell. It is rarely acceptable to use
MODFLOW cell dimensions to closely simulate physical
variations in layers when they pinch out.
* I have not used the WHS solver sold by waterloo
hydrogeologic. while i therefore cannot comment on
this solver and its claimed superiority to SIP, i feel
quite sure that SIP has been the best performing
solver for almost all models i have constructed over
the past few years, and never had problems with mass
balance which could not be successfully overcome by
using SIP. i do recall a paper published in Ground
Water years ago when WHS proponents at software
developer Waterloo Hydrogeologic compared their WHS to
SIP and PCG (among other public domain solvers). i
felt that sip had been shortchanged and misrepresented
in their analysis in that they had claimed that sip
yielded a much greater mass balance error than that
obtained when using their whs solver. what they had
failed to do in their analysis, was to accordingly
decrease the HCLOSE with their corresponding decrease
in the acceleration parameter. this is the equivalent
of not closing tightly enough on heads, and therefore,
ending up with an excess mass balance error. this was
an improper use of SIP.
I have found that lowering of the acceleration
parameter, and corresponding decrease in the HCLOSE
will yield a very low (acceptable) to zero mass
balance error, but one must be careful in that the
acceleration parameter is not set so low that the
model converges prematurely with insufficient head
change.
* Check all inputs in the flow model first. Make sure
your flows are realistic. Make sure your K's and
recharge are realistic. Refine your grid and use
dispersivity values that will minimize numerical
dispersion. Make sure your grid cell size complies
with appropriate Peclet criteria (as a rule of thumb,
for finite diferences, Pe should be ~ 2; that means
your grid size should be roughly 2* your dispersivity
value, in the area where, for MOC, this can be
higher). I suggest your read some transport modelling
books that explain this in detail. Be careful with
using constant concentrations, they can act as a
source, but also as sinks (if he concentration in
neihbouring cells is higher than the ones you
specified in the constant concentration node).
* When she is referring to inflow, in plane, and
outflow, I think what she is doing is looking at the
color coding for the velocity vectors or pathlines.
When she sees that there are very few arrows or
pathlines with a green color (indicating 'inplane' or
flat horizontal flow in the layer) she gets concerned
for some reason. Most likely the lack of 'in plane'
flow has very little to do with anything she is
concerned about, it just reflects the fact that she
has slight vertical gradients in the model.
WRT to the vanishing concentrations, you could also
suggest her to make sure she didn't input a default
degradation rate of 0.5 or something very high and
then forgot about it, or the other possibility is she
has assigned a sorption coefficient of 1 (mistaking it
for a retardation coefficient), or perhaps just a very
large sorption coefficient of 0.01 L/mg which would
cause the plume not to move at all, thus giving the
impression that it is disappearing from the model,
when in fact it hasn't moved at all. Another
possibility is that she initially assigned
non-conservative values of sorption and decay
coefficients when she set up the transport model
scenario, and she is now trying to modify these values
in the Setup/Transport Engine dialog instead of in the
Input mode (I've seen this problem a few times) or
Visual MODFLOW.
Finally, the fact that the solution solves in two
iterations seems to indicate that the total run time
of the MT3DMS solution may have been left as the
default of 1 day (perhaps she assumed it automatically
picks up the end time of the flow simulation). She
can change this by selecting Run/MT3DMS/Output Times
and entering the desired Simulation Time.
* The simplest way of defining a starting
concentration is to use the Recharge Coverage and
specify a polygon shape that denotes the contaminant
concentration to be applied to the model.
* What to do when your contaminant plume does not
migrate as expected.
When using MT3D or RT3D for a contaminant transport
simulation, if the plume fails to move as expected (or
does not appear at all in your Visual MODFLOW output),
here are a few common causes and their solutions.
Problem #1: Overlay is not active, or masked by
another overlay
Solution #1: As with Head Equipotentials, Particles,
and even Basemaps and other overlays, you must make
the Concentration overlay active in order to see it.
Click the F9-Overlay button at the bottom of your
screen, and ensure the overlay has been checked off
(to make it active). It is also possible that other
overlays are masking your concentrations. To resolve
this, change the Overlay Order setting to User
Defined, then highlight the Concentration overlay, and
use the arrow buttons to move it up the list.
Problem #2: Simulation Output time
Solution #2: In Visual MODFLOW, the Simulation Output
time can be different for your flow and transport
simulations. Check to see that you have defined the
correct simulation time(s) in the Run Menu, by
selecting MT3D (or RT3D) / Output - Time Steps.
Additionally, in the Output Menu of Visual MODFLOW,
ensure that you have selected the Concentration
overlay as the active overlay, then select the Time
button in the left toolbar, to change output times as
desired.
Problem #3: No concentration input assigned, or not
assigned properly
Solution #3: Ensure that you have correctly defined at
least one cell with an Initial Concentration, or a
transport boundary condition of one of the following
types: Constant Concentration, Recharge Concentration,
Evapotranspiration Concentration, or Point Source.
Please NOTE that Concentration values entered for
Concentration Observation Wells are used for
calibration purposes only; they do not contribute mass
to a transport simulation.
Problem #4: Inadequate flow gradient
Solution #4: Before running your transport simulation,
run just the flow simulation (MODFLOW). Using
Pathlines or Velocity Vectors, ensure that there is a
sufficient flow gradient to cause plume migration.
Problem #5: Incorrect reaction parameters
Solution #5: Check the reaction options in the Main
Menu, by clicking on Setup / Numeric Engines /
Transport. Check that the correct Sorption and
Reaction options have been selected.
First order decay rates (dissolved and sorbed phases)
may have a tremendous impact on the plume mass, since
during the simulation, some contaminant mass may be
removed from the model. If the decay rate is too high,
your plume will show very small concentrations, and/or
will not be visible at all at later simulation times.
Decay rates (due to biodegradation or other
mass-removal processes) can be taken from literature
values, but this should be done with caution, as this
parameter is highly site-specific for most compounds.
A good reference on decay rates used in natural
attenuation studies can be found in:
Wiedemeier et al., 1999: Technical Protocol for
Implementing the Intrinsic Remediation with Long-Term
Monitoring Option for Natural Attenuation of Dissolved
Phase Fuel Contamination in Ground Water. Air Force
Center for Environmental Excellence, Brooks, AFB.
This document can be downloaded from:
http://www.afcee.brooks.af.mil/products/techtrans/monitorednaturalattenuation/pr\
otocols.asp
The decay rate (l, or sometimes called Kd, with units
of 1/day), is typically obtained from half-life
values, converted into appropriate units using the
following relationship:
l = ln(2)/t1/2
Where t1/2 = half-life of the compound
In addition, check that your Kd value is correctly
defined in the Species Parameters tab. A very large Kd
value will result in an extremely high retardation
factor, which can result in lack of contaminant
movement through your model.
For typical organic compounds (such as TCE, DCE, PCE,
BTEX, etc.) where linear, reversible sorption can be
assumed, retardation will be calculated using the
following formula:
Retardation = 1+ (Bulk Density/porosity)*(Kd)
Where Kd = Partition coefficient
For hydrophobic organics, Kd can be determined using
the relationship below:
Kd = Koc*foc
Koc - octanol-carbon coefficient
foc - organic carbon fraction in the aquifer
A more detailed overview on Kd's can be found in:
US-EPA, 1999. Understanding variation in Partition
Coefficient, Kd, values. EPA
402-R-99-004A&B. US-EPA Office of Air and Radiation.
This document can be downloaded from:
http://www.epa.gov/radiation/cleanup/partition.htm
* From the Modflow standpoint, water that exits the GW
system through of a drain cell is accounted for in the
budget, but is otherwise not simulated. The situation
for river cells is similar--Modflow does not simulate
any flow in the river, it only simulates exhange
between the GW system and each individual river cell.
So there is no way to route water from a drain cell to
a river. The Streamflow Routing (STR) Package, on the
other hand, does simulate flow in surface-water
streams, accounting for flow rates in the stream and
calculating stream stage, which is then used as the
external head in the GW/SW exchange calculation. If
you want to simulate exchange between drains and
rivers, you could use the STR Package for both types
of features.
* How to import modflow model files to gwvistas 4?
Select File/New and click the MODFLOW button. On the
next dialog, click browse to go find the name file
(*.nam). If this is an older MODFLOW88 dataset, then
browse to find the *.bas file. Some datasets
(especially those that were created without the use of
a preprocessor) can be troublesome.
* I want to input separately 2 sets of recharge into a
modflow model: (1) Effective recharge from rainfall,
and (2) urban leakage (same format as the (1)), which
will overlap. Since both components are fairly complex
and over a long time (1200 Stress Periods), I would
like to keep them as independent as possible (avoiding
the data compilation option, if you see what I mean).
It is possible to do what you want using just the
Recharge package. Here is how you do it.
Define each recharge distribution for each stress
period using parameters. You can use one set of
parameters for the rainfall and another for the urban
leakage. With each parameter, you can use multiplier
arrays and zone arrays to define the spatial
distribution of the recharge. Then, for each stress
period, use the parameters for that stress period to
apply recharge from both rainfall and urban leakage.
MODFLOW-2000 will add the contributions from all the
parameters you use in a stress period to determine the
total recharge.
You should be able to do this with any reasonably
up-to-date GUI for MODFLOW-2000. If you are using a
GUI and you can't figure out how to do this, contact
the GUI developer for assistance. If you aren't using
a GUI, you can check the input format in the Online
Guide for MODFLOW-2000 at
http://water.usgs.gov/nrp/gwsoftware/modflow2000/MFDOC/guide.html
or in the original MODFLOW documentation as modified
in "Time-varying-parameters.pdf" (distributed with
MODFLOW-2000).
* Since I know you are using Modflow VKD (based on
MF96, not MF2K) and that the wells package is almost
certainly being used for many abstraction wells, I
suggest 2 routes:
1. A FORTRAN utility to combine two recharge files - a
days work? 2. To use a MF package that you aren't
already using - but with some manipulation e.g. the
rivers package. By setting the stage of the river as
above any elevation in the model (1000m?) and the
conductance equal to the quantity you want to recharge
for that SP - with a 1 m difference between stage and
bottom elevation you will get the appropriate amount
leaking (recharge) to each cell.
You can achieve the same result with the drains
package by specifying 2 drains in each cell. The trick
is to have one with a positive conductance and the
other negative, but the same value. Make the
difference in elevation 1m and the magnitude of the
two conductance values the quantity you want to
leak/abstract. If the elevation is outside the range
of variation in the model, you end up with a constant
recharge/abstraction from the model.
For composite/trick boundary conditions of this type I
suggest drawing figures for them like those in the
MF88 book, it will help to understand what I'm trying
to say.
* Design the shoreline?
Depending if you are using FEMWATER or MODFLOW, it is
handled differently. With FEMWATER, you want the
boundary of your 3D mesh to follow the shoreline. With
MODFLOW, you are working with a 3D grid. So, you need
to mark the cells that contain the shoreline with a
fixed head boundary condition, and the cells outside
this area will be disabled.
If you are attempting to model the interaction with
the sea bed, then you will need to set the top
elevations of the mesh or grid to match that of the
sea bed. However, generally you end your model at the
shoreline.
* MT3D Performance
What you need most depends on where your bottle-neck
occurs. You need to monitor CPU and RAM usage on the
computer during the MT3D run. If you run Windows 2000
or XP, you can right click (for a right-handed
pointing device) on the Taskbar (grey bar at bottom of
screen), then select Task Manager in the menu pop-up.
Once Windows Task Manager opens, select the tab
labeled "Performance". "Performance" shows CPU usage
graphically and memory usage in numeric form. If the
"CPU Usage History" (top graph) stays maxed at 100%,
then a CPU speed increase should help. In parallel,
observe the "Physical Memory" values. If the
"Available" value becomes a small fraction of the
"Total", AND the "Commit Charge, Total" exceeds the
"Physical Memory, Total" then you are likely to have a
RAM-limited condition. In this case, more RAM would
help. With 300,000 cells, consider 1 Gbyte or more. If
both things are happening (unlikely), then upgrading
CPU and RAM should help. Be aware that upgrading one
component sometimes results in the other becoming the
limiting condition. That is why it is "unlikely" both
limits are happening simultaneously. Usually one tops
out before the other. If you run Win98... consider
upgrading the OS.
* There are various things that you have to do to get
Surfact running in Vista 3:
1. You can only have a limited number of packages.
For example, if you are doing contaminant transport
modelling then you have to turn some other pacakges
off, otherwise Surfact will not run e.g. you can turn
the cell by cell flow packages off (just type 0 into
the packages number in Model - Modflow - Packages).
Another pace you can turn packages off is in the
output control: Turn off the drawdown unit.
2. You have to modify some things in the Model -
Modflow options and some in the Modflow - Surfact
options. These are:
Model - Modflow - Packages: change modflow version to
surfact; change solver to PCG4; and untick
automatically reset package units
Model - Modflow - BCF package: tick the box to use
the BCF4 package
Model - Surfact - Packages: add a unit number (one
that you have not yet used) and tick the box for BCF4;
add the unit number to PCG4 and tick the box (use same
unit number as shown in Model - Modflow- Packages);
add a unit number and tick box to RSF4 is you want the
model to simulate surface seepages (and remeber to
turn this unit on in Model - Surfact - RSF4 package).
Model - Paths to models: set modflowwin32 option to
DO NOT USE; put in correct path for surfact in the
modflow box.
I can't think of anything else right now - I always
forget one thing and spend a couple of hours wondering
why surfact won't run. If you have any difficulties
it would be helpful to know if the surfact Dos window
displays and if so, what it says in the window.
* The most common problem when using SURFACT is
setting up the program file. Select Model/Paths to
Models. Change the MODFLOWwin32 Option at the top to
"do not use". That tells Vistas that you are not
using one of our model DLLs. Then change the MODFLOW
program from MFWIN32.DLL to whatever your SURFACT
program is (usually it is msft.exe).
* I believe that if you are using the latest version
of SURFACT (V2.2) that problem 1. below is no longer
an issue. It used to be that SURFACT could only open
a limited number of files but that is no longer the
case. Also, if you upgrade to Vistas Version 4 and
SURFACT V2.2 the link between the two programs is
easier to establish. The same holds true for all of
the other versions of MODFLOW that Vistas supports
(MODFLOW88, MODFLOW96 in double precision,
MODFLOW2000, MODFLOWT, MODFLOW-SURFACT, SEAWAT, and
SEAWAT2000).
* VS2DI or VS2DT, being a Richards equation-based
models have certain PROs and CONs when used for
groundwater recharge estimation:
Pros: the Richards equation models are the most
theoretically based and allow representation of the
flow processes in porous mediums more realistically
than the water-balance models. They have been well
tested against field and laboratory experiments and
proved to provide good correlation with observed
results.
Cons: the major complicity of the Richards equation,
comparing to the saturated flow models, is that its
coefficients are non-linear functions of the pressure
potential. To approximate these functions, three
different algebraic equations are usually used (named
after their authors): Brooks and Corey's, Gardner's,
and van Genuchten's. Richards equation can be solved
with a very limited number of boundary conditions. The
condition for water at the boundary can be specified
either as the flux of water across the boundary, the
head at the boundary or as a combination of specified
head and specified flux. The Richards equation with
these boundary conditions is a nonlinear partial
difference equation that has no close-form or
analytical solution. To solve the Richards equation,
a finite-difference method of numerical approximation
is applied in VS2DI. Searching for a best numerical
method for the Richards equation became a special
field in hydrologic science, particularly in 1980's,
however, almost all implemented approaches cannot
assure that the model will unconditionally converge
and simulation results will be obtained. It is an art
to get the model to work correctly (produce results
for the whole simulation period with a good water
balance) when you have varying flow boundary
conditions in your profile. Our experience also proved
that applications of Richards equation-based models to
highly heterogeneous soils with variable hydraulic
properties can be extremely difficult to execute and
time consuming.
These days there more and more examples when less
sophisticated in flow equation but much more advanced
in terms of weather/plant effects water-balance model
HELP is used to estimate groundwater recharge.
* I will suggest you keep the north and south boundary
as variable head boundary. This I am suggesting you
treating there is no river, lake etc. If these
features are present on north or south side of model
domain, then you have look for another type of
boundary. Regarding limited observation well data and
that too is limited to layer1, then it will not be
possible to do any realistic modelling. If there is no
scope of generating additional data, i would like to
suggest that you confine your modelling activity to
first layer only.
* What makes a good correlation depends on what your
expectations are. If you are conducting exploratory
research, maybe 0.2 isn’t bad. If you are testing a
known process having some natural variability, 0.6
might be acceptable. But if you are calibrating
instruments, maybe 0.9 isn’t good enough.
If you don’t have any clear expectations, how do you
tell if a correlation is good? The answer comes in
three parts.
1. Value - Square the correlation coefficient (called
the coefficient of determination or just R-square).
R-square is the proportion of variation in the
dependent variable (y) that can be accounted for by
the independent variable (x). You might be able to
decide how good your correlation is from a gut feel
for how much of the variability you wanted your model
to account for.
2. Significance - Every calculated correlation
coefficient is an estimate. The “real” value may be
somewhat more or somewhat less. You can conduct a
statistical test to determine if the correlation you
calculated is different from zero (or some other
number if it’s relevant). The larger the calculated
correlation and the greater the number of samples, the
more likely the correlation will be significantly
different from zero. For example, a correlation of
0.59 (R-square of 0.35) would be significantly greater
than zero based on about 25 samples, but a correlation
of 0.01 wouldn’t be significant with 250 samples.
3. Plots - You should always plot the data used to
calculate a correlation to ensure that the coefficient
adequately represents the relationship. Specifically,
the data should be linearly related and free of
outliers. There are a few other things to look for
(e.g., hidden trends, autocorrelation) that I won’t go
into here.
So, the reviewer who said that “the "R square" value
of 0.35 has no significance and is just as good or as
bad as say 0.01” would only be correct if she looked
at a statistical test of whether the value was
significantly different from zero. R square does not
need to be more than any particular value to draw a
comparison. Remember, too, that “no relationship” may
also be an important finding.
* If you are considering GUI's for your project, you
may want to look at Visual MODFLOW Pro. In
particular, if cell splitting, or grid refinement is
an issue for you. Visual MODFLOW includes two
distinct features that help users with this.
1) Cell refinement tool
2) Grid smoothing tool
1) Cell refinement/splitting tool: You'll need no
more than a few clicks to edit your grid in a very
flexible manner. To split your cells, just click on
'Refine by ...", and specify how many times you want
the cell to be split into (2, 3, 4...). Then, select
the area you need to refine with your mouse.You can
apply this to one row or column, or all cells in the
domain - whatever you wish. The same applies for
splitting layers and coarsening the grid.
2) Grid smoothing tool: After grid refinement, you may
want to use the grid smoothing routine to produce a
smooth transition between coarser areas to highly
discretized ones. Again, just a few clicks. This is
actually a perfect tool to help you better understand
the effects grid size and refinement will have on your
model results.
Another feature that may be useful for you is Visual
MODFLOW Pro's batch capabilities. It will allow you
to prepare all data input files in different model
projects and run them in 'batch mode'.
* The interpretation method is different according to
the geology. You have methods for porous media, others
for fissured aquifer, others for double porosity
media. Methods also vary according to the type of
aquifer (confined or unconfined; semi-confined with a
leaky aquifer...) and corrections can be made
according to the type of well (partially penetrtaing
well; pumping well with head loss; skin effect and so
on). Finally, boundary effects (barrier or recharge)
may affect significantly your interpretation.
In order to remain pragmatic I would suggest you to
start with the simplest method : the Theis formula,
(or even the Jacob approximation if your pumping time
is big enough) and check wether you get a good fit or
not with realistic parameters. Even a fissured
unconfined aquifer can be interpreted with Theis when
your radius of influence is wide so that the fissure
network can be assimilated to an homogeneous
equivallent porous media and the depletion of the
water level is moderate compared to the thickness of
the aquifer. This should give you a rough estimate of
your transmissivity, which is in many cases,
sufficient.
If you need more accuracy you can use specific
softwares. You will find on the net many softwares
proposing many different methods. You don't need Pest
as they have their own fitting engine. AQTESOLV for
instance proposes methods with well storage effect.
However, as soon as a software proposes its own
adjustement, it's becoming very difficult to know
what's you're doing and you end up playing a video
game. So be carefull, especially if you lack
experience in this domain, not to use complex methods
with many parameters which will end in a perfect fit
but with irrealistic results. In my company (French
geological survey)we use ISAPE, a software which is no
more commercialised, but whose philosophy is to let
the user propose realistic values and where you can
add or remove well effects or boundary influence. I
wish this approach were more widespread.
* I think your scenario will represent two different
geologic materials with peculiar intrinsic properties.
Hence, I suppose this will require two separate
simulations. To the best of my knowledge, MODFLOW 2000
only allow one K matrix values per layer per
simulation and this is incorporated within the flow
package. However, if the introduction of the permeable
barrier is controlled along defined specific paths or
unique relatively smaller area(s), then you can use
one simulation with two stress periods and incorporate
Horizontal Flow Barrier Package in the second period
to account for the permeable barrier distribution.
This is not suppose to be of much problem especially
if you incorporate your modflow with GIS package like
GRASS GIS.
* Sophisticated modeling programs like Visual Modflow
Pro, or any of a number of similar packages, will run
properly with a variety of inputs that may not be
physically realistic - and thus provide garbage for
output. With that in mind, here are some thoughts on
your questions:
1) You may divide a single aquifer into more than one
layer if there is some reason to look at vertical
stratification within the aquifer. For example, a
thick aquifer may have different hydraulic or
transport properties in different vertical zones. You
may also divide a single aquifer into several layers
if you want to examine the vertical flow patterns due
to pumping from different zones within the aquifer.
2) The top of Layer 1 could be the ground surface,
the water table (not as common because it can move
vertically), or the top of the uppermost aquifer or
aquitard of interest depending on the physical system
being modeled.
3) You'll need to assign boundary conditions no
matter what the size of the physical system is. If
you don't have natural physical boundaries, one
strategy is to assign boundary conditions at a
distance far enough away from the area of interest to
minimize the effects of boundary assumptions on the
solution.
* It is appropriate to use a single layer if you feel
that it is reasonable to ignore vertical flow in your
model. Assuming that you would be using the Layer
Property Flow (LPF) Package of Modflow-2000, and if
the aquifer represented by layer 1 is not overlain by
a confining unit, then specifying the top of layer 1
as ground surface is reasonable. The reason that you
would be better off this way than specifying the water
table elevation as the layer top is that the LPF
Package only provides two options with respect to the
confined/unconfined status of a layer: Confined or
Convertible. If the head in a cell goes above the
specified top of a convertible layer, the cell is
treated as confined. Every model needs to have at
least one fixed head, either as a constant-head cell
or as a fixed external head (such as the stage at a
river cell), or the solver will not be able to reach a
solution. You may need to expand the domain of your
problem to encompass a fixed head.
* 1- Model design depends greatly on your project
goals. For example, you could have one aquifer, but an
overlying layer (and/or underlying layer) as well. Or,
you could be modelling just 1 aquifer, but split it up
into several layers in VMOD to provide more detailed
flow information (i.e. if the aquifer is 100 feet
thick, having just 1 layer will not provide very
detailed output. You can subdivide the 1 "real-world"
layer into 10 "model" layers, all with the same
hydrological properties, in order to obtain more
detailed output). Or, you can simply design a 1-layer
model if that is all your project requires.
2- In Visual MODFLOW, Layer 1 represents the uppermost
layer of your profile, and the top of Layer 1 is
therefore the ground surface. Layers in Visual MODFLOW
represent soil layers (or conceptual soil
layers)....the location of groundwater in these layers
is determined by your model inputs, and the resulting
calculations of the flow model.
3- The assignment of boundary conditions is a question
that often goes beyond the scope of Technical Support,
and enters the realm of Extended Modeling Support.
However, to provide you with some guidelines:
-If you have no "obvious" water inputs (streams,
rivers, lakes, injection wells, recharge from
rainfall, etc.), you can try assigning an upgradient
equipotential line, and downgradient
equipotentialline, using Constant Head Cells at the
upgradient and downgradient edges of your model, to
represent the regional water table (other boundaries
may be more appropriate, depending on your specific
model domain and objectives). You can then add
additional inputs (extraction wells, contaminant
sources, etc.) to the model region, which will be
influenced by your regional flow gradient.
4- I would recommend taking some time to run through
the Tutorials included with your Visual MODFLOW
software (the PDF instruction files are located on
your installation CD-Rom, and the files are
automatically copied to the Tutorial subfolder in your
Visual MODFLOW program folder). These tutorials are
designed to teach you how to work with your software,
and how to design a model, import data for model
inputs, run the various packages, calibrate your
model, examine your output in 2D and 3D, and export
data.
* You can use the field interpolator program in the
PMWIN package. Using the field interpolator you can
interpoltae the field data in txt file to the grid
point of your model. On the other hand, you can import
any dxf file which illustrate the changes in hydraulic
properties to help you in the graphical interface.
* Upwind discretization always has an artificial
diffusion term no mater how refined your grid is (even
thought it diminishes with grid refinement). Central
discretization always produces an artificial
dispersion term that causes "wigles" however you can't
control it with grid refinement. For almost any Pellet
number the upwind scheme will produce positive
coefficients for your coefficient matrix, while that
isn't true for central differences. However central
differences has "second order accuracy" while upwind
only has first order. You can visualize numerical
diffusion and dispersion mathematically by deriving
the "equivalent or modified equation" see
http://widget.ecn.purdue.edu/~jmurthy/me608/main.pdf
for some cool notes on this (as good as any book I've
read).
Physically you can visualize numerical diffusion by
imagining a 1D discretization of a domain | : | : | :
| where | are faces and : is the center of the cells.
If your initial property is 1 on a given cell say i
and 0 on all others it would look like this:
| 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0
So using upwind with a courant = v dt / dx of say 0.5
and a velocity from left to right after the first time
step the accurate solution would be something like
(zooming on cell i):
| 0 { 0.5 | 0.5 } 0 |
Note that I have created a new cell delimited by the
{} brackets this "new cell" that doesn't exist in our
domain is exactly half of cell i and alf of cell i+1.
The property's value will be 0.5 inside this new cell
and 0 outside it (meaning that cell i and i+1 would
have half with 0.5 and half with 0). This would be the
accurate solution because a courant of 0.5 makes the
property shift half a cell every time step. However we
are bounded to our initial discretization so the
solution we will obtain will be:
| 0 | 0.5 | 0.5 |
so you can see than instead of having a 0.5 of
property in a volume the size of a cell we have 0.5 in
a volume the size of 2 cell thus lowering the
concentration. This happened because the definition of
concentration is C = lim vol ->0 DM/DVOL and we
implemented it as DM/DVOL. If we would diminish the
size of our grid so that currant = 1 we could obtain
the exact solution. So the smaller your grid is the
more accurate your solution will be. This is the
physically correct way of solving the diffusion
problem another way is to use higher order schemes
witch usually maintain the sharpness of the gradients
but usually remove mass from all the wrong places
(even thought they conserve it). Looking at the same
example a central differences discretization would
derive something like:
| -0.25 | 0.75 | 0.25 |
Cell i-1 will produce a negative property because the
concentration al the face between i-1 and i is 0.5
cell i +1 will obtain the accurate concentration of
0.25 (0.5 in half the volume of a cell). But we are
producing the famous "wigles" close to the properties
gradient. There are smarter second order schemes like
qwick or TVD schemes.
* In visual MODFLOW there is provision for importing
MODFLOW files (*.bas files). In PMWin there is
provision for conversion of MODFLOW88/96 (*.nam). I
have tried to import *.bas file in Visual MODFLOW and
found that model data is not correctly coming to
model. These options may be available in GMS but I am
unable to locate the exact sub-menu. Number of options
is available for opening different format files In the
FILE menu. But It does not permit opening of *.bas or
*.nam files. This option must be in different menu.
-----------------------------------------------------------------
__________________________________
Do you Yahoo!?
Dress up your holiday email, Hollywood style. Learn more.
http://celebrity.mail.yahoo.com