Dear Sir/Madam,

I am staying at Ranchi, the capital of Jharkhand, in a building comprising of 34
flats. I would like to know the minimum storage capacity of overhead water
tanks. Please give the details of calculation.

Note: - There is no underground water tank. The overhead tanks are to be fed
through deep well boring and used to service all the needs of the residents.

regards,
Anita Bhatt



Fri Jul 18, 2008 6:49 am

anitajnu2001
Offline Offline
Send Email Send Email

Forward
Message #583 of 727 |
Expand Messages Author Sort by Date

Dear Sir/Madam, I am staying at Ranchi, the capital of Jharkhand, in a building comprising of 34 flats. I would like to know the minimum storage capacity of...
anita bhatt
anitajnu2001
Offline Send Email
Jul 18, 2008
8:36 am

Madam, The overhead tank should supply about 34 X 1500 litres (assuming 5 persons in a house) i.e, 51,000 litres of water per day for comfortable use of...
S V Vijayakumar
vkumarsv@...
Send Email
Jul 18, 2008
10:59 am

Dear Anita,   For designing a storage tank one of the important factor is the average daily usage of water per capita, which is different for different areas...
habib rehman
habib675
Offline Send Email
Jul 21, 2008
4:54 am

Dear Anita,   For designing a storage tank one of the important factor is the average daily usage of water per capita, which is different for different areas...